Motor power (U/V/W/PE), EM brake (EM+/EM-, EM1/EM2), and motor temperature sensor (T+/T-)
terminals
Connector variant
Frame size
Wall-mounted converter
FSA
FSB
FSC
Glanded variant
Frame size
Wall-mounted converter
FSA
FSB
FSC
Frame size
Wall-mounted converter
FSA/FSB/FSC EM+/EM-,
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Terminal
U/V/W/PE
EM+/EM-, EM1/EM2
T+/T-
U/V/W/PE
EM+/EM-
T+/T-
U/V/W/PE
EM+/EM-, EM1/EM2
T+/T-
Terminal
Cable lug
U/V/W
Screw-type
Fork-type
PE
Ring-type
U/V/W
Screw-type
Fork-type
PE
Ring-type
U/V/W
Screw-type
Fork-type
PE
Ring-type
Terminal
Spring-type Pin-type
EM1/EM2
T+/T-
Cross-section for stranded conductor
4 × 1.5 mm
to 4 mm
2
2 × 0.75 mm
to 4 mm
2
2 × 0.75 mm
to 1.5 mm
2
4 × 2.5 mm
to 4 mm
2
2 × 0.75 mm
to 4 mm
2
2 × 0.75 mm
to 1.5 mm
2
4 × 4 mm
(AWG 12 to AWG 10)
2
2 × 0.75 mm
to 4 mm
2
2 × 0.75 mm
to 1.5 mm
2
Cross-section for
stranded conductor
4 × 2.5 mm
to 4 mm
2
(AWG 13 to AWG 12)
4 × 2.5 mm
to 4 mm
2
(AWG 13 to AWG 10)
4 × 4 mm
2
(AWG 12 to AWG 10)
Cable lug
Cross-section for stranded
conductor
2 × 0.75 mm
(AWG 18 to AWG 12)
2 × 0.75 mm
(AWG 18 to AWG 16)
4.8 Cables and connectors
(AWG 16 to AWG 12)
2
(AWG 18 to AWG 12)
2
(AWG 18 to AWG 16)
2
(AWG 14 to AWG 10)
2
(AWG 18 to AWG 12)
2
(AWG 18 to AWG 16)
2
(AWG 18 to AWG 12)
2
(AWG 18 to AWG 16)
2
Screw tightening torque
1.0 Nm (8.9 lbf.in)
2
2.2 Nm (19.5 lbf.in)
1.0 Nm (8.9 lbf.in)
2
2.2 Nm (19.5 lbf.in)
1.0 Nm (8.9 lbf.in)
2.2 Nm (19.5 lbf.in)
Crimping
length
to 4 mm
12 mm
2
2
to 1.5 mm
10 mm
2
2
Wiring