Siemens SINAMICS G115D Operating Instructions Manual page 362

Distributed drive for conveyor technology control
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
10.1 Technical data of the G115D converter with SIMOGEAR geared motor
Safety Integrated
Property
Safety function
Environmental conditions
Property
Surrounding
Storage &
temperature
transport
Operation
Vibration severity
Pollution degree
Relative humidity
Installation altitude
Cooling method
Cooling air
Degree of protection
2)
Weight
For UL-compliant applications, the maximum surrounding temperature for a glanded variant with daisy chain is 48 °C.
1)
For the specific degree of protection of your converter, refer to the rating plate on your component.
2)
360
Explanation
STO, SIL2 / PL d / Category 3
STO fulfils the requirements of the following standards:
SIL 2 according to IEC61508, part 1 to 3 (2010)
PL d according to IEC61800-5-2 (2016)
Category 3 according to ISO13849 part 1 (2015)
The function STO corresponds to stop category 0 according to IEC60204 (2005)
Response time: 20 ms
The response time of the Safe Torque Off function is the time between selecting
the function and the function becoming active.
Probability of failures:
Probability of dangerous failure per hour: PFH < 50×10
PFH according to IEC 61800-5-2
Probability of dangerous failure on demand: PFD < 50×10
PFD according to IEC 61508
Mission time: 20 years
You may not operate converters with integrated safety functions for longer than
the mission time. The mission time starts when the device is delivered. The mission
time cannot be extended. This is the case even if a service department checks the
converter – or in the meantime, the converter was decommissioned.
Explanation
-25 °C to +50 °C
-30 °C to +55 °C
1)
Torque derating as a function of the surrounding temperature (Page 366)
Grade A according to IEC 60034-14
Mounting the G115D Motor Mounted drive (Page 35)
Suitable for pollution degree 2 environment according to EN 61800-5-1
< 95% (non-condensation, no icing, no salt spray)
Up to 1000 m above sea level without derating
Above 1000 m (up to 4000 m) with derating
Torque derating as a function of the installation altitude (Page 366)
Active cooling with the motor fan
Clean and dry air
G115D converter with SIMOGEAR geared motor: UL enclosed type
Siemens recommends that you use the cables and connectors given in the linked
chapter below to satisfy the suitable rating of the UL enclosed type.
Cables and connectors (Page 62)
The weight is stated on the rating plate.
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002