Additional information on the SIMOGEAR geared motor
11.1 General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
11.1.15.8

Sound energy level

SIMOGEAR geared motors have noise levels below the permissible noise levels defined for
gearboxes in VDI guideline 2159 and for motors in IEC 60034-9. Interaction with gearboxes
causes the motor noise values L
The circumferential velocity of the motor pinion has a significant influence on the additional
gearbox noise level. As a consequence, higher speeds or lower ratios result in higher noise.
SIMOGEAR geared motors provide a decisive advantage here, since the motor plug-on pinion
allows transmission ratios of up to 12 in the input stage.
Code
L
pfA
L
WA
External noise
Noise not generated by the gearbox but emitted from it are not taken into consideration.
Noise emitted by the drive and driven machines or the base are also not taken into
consideration. Even when the noise from the gearbox have been transferred there.
11.1.16

Spare parts

11.1.16.1

Stocking of spare parts

By stocking the most important spare and wearing parts on site, you can ensure that the
gearbox or geared motor is ready for use at any time.
NOTICE
Safety impairment caused by inferior products
The installation and/or use of inferior products can have a negative impact on the design
characteristics of the geared motor and may consequently impair the active and/or passive
safety features of the machine.
Siemens AG states explicitly that only spare parts and accessories supplied by Siemens have
been tested and approved by Siemens.
If you do not use original spare parts and original accessories, Siemens AG excludes every
liability and warranty.
Siemens AG accepts the warranty only for original spare parts.
Note that special manufacturing and delivery specifications often apply to individual
components. All spare parts offered by Siemens AG are state-of-the-art and conform to the
latest legal regulations.
402
or L
pfA
WA
Description
A-weighted enveloping surface sound pressure level
Sound power level
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
to increase on average by 3 to 5 dB (A).
Unit
dB (A)
dB (A)