3. The end customer inserts the memory card and switches on the power supply of the
converter.
4. When powering up, the converter checks the serial numbers of the card and when there is a
match, the converter goes into the "ready to start" state.
If the numbers do not match, then the converter signals fault F13100 (no valid memory
card).
You have transferred the converter settings to the new converter.
Option 2: The machine manufacturer knows the serial number of the new converter and
the serial number of the memory card
1. The end customer provides the machine manufacturer with the following information:
– For which machine must the converter be replaced?
– What is the serial number (r7758) of the new converter?
– What is the serial number of the memory card?
2. The machine manufacturer performs the following steps online on the prototype machine:
– Deactivating know-how protection
– Enter the serial number of the new converter in p7759.
– Enter the serial number of the customer's memory card as reference serial number in
– Activate know-how protection with copy protection. "Copy RAM to ROM" must be
– Write the configuration with p0971 = 1 to the memory card.
– Copy the encrypted project from the card to the associated PC.
– Send the encrypted project to the end customer, e.g. via e-mail.
3. The end customer copies the project to the Siemens memory card that belongs to the
machine, inserts it in the converter and switches on the power supply of the converter.
4. When powering up, the converter checks the serial numbers of the card and when there is a
match, the converter goes into the "ready to start" state.
If the numbers do not match, then the converter signals fault F13100 (no valid memory
card).
You have transferred the converter settings to the new converter.
SINAMICS G115D distributed drive
Operating Instructions, 12/2020, FW V4.7 SP13, A5E48681219B-002
Activating and deactivating know-how protection (Page 318)
p7769.
activated.
Activating and deactivating know-how protection (Page 318)
Corrective maintenance
9.2 Replacing the converter
341