B.3 Control Mode Dependent Parameter Default Values
B.3 Control Mode Dependent Parameter Default Values
The tables below list parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2). These
parameters are initialized to the shown values if the control mode is changed.
u

A1-02 (Motor 1 Control Mode) Dependent Parameters

Table B.1 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
Parameter
b3-02
Speed Search deactivation current
Current Control Gain during Speed Search (Speed
b3-08
Estimation Type)
b8-02
Energy Saving gain
C2-01
S-curve time at acceleration start
C3-01
Slip compensation gain
C3-02
Slip compensation time constant
C4-01
Torque compensation gain
C4-02
Torque comp. primary delay time
C6-02
Carrier frequency
E1-04
Maximum output frequency
E1-05
Maximum output voltage
E1-06
Base Frequency
E1-07
Middle output frequency
E1-08
Middle output freq. voltage
E1-09
Minimum output frequency
E1-10
Minimum output voltage
E1-11
Middle output frequency 2
E1-12
Middle output freq. voltage 2
<2>
E1-13
Base voltage
L1-01
Motor protection selection
L3-20
Main power circuit voltage adjustment gain
L3-21
Accel/decel rate calculation gain
<1> Default setting value is dependent on parameter o2-04, Drive Model Selection.
<2> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<3> Default setting value is dependent on parameter E5-01, Motor Code Selection.
<4> The default value is for the following localized drives: Japan (Model code: CIMR-VAoA) and Asia (Model code: CIMR-VToA)
China Localized Drive Default Values on page 381
378
Description
<2>
<2>
<2>
<2>
for the default values of China localized (Model code: CIMR-VBoA) drives.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Setting Range
Resolution
0 to 200
1%
0.00 to 6.00
0.0 to 10.0
0.1
0.00 to 10.00
0.01 s
0.0 to 2.5
0.1
0 to 10000
1 ms
0.00 to 2.50
0.01
0 to 10000
1 ms
1 to F
1
40.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 400.0
0.1 Hz
0.0 to 255.0
0.1 V
0.0 to 255.0
0.1 V
0 to 4
0.00 to 5.00
0.01
0.00 to 200.00
0.01
Control Modes (A1-02)
V/f (0)
OLV (2)
PM (5)
120
100
<1>
<1>
0.30
0.50
0.50
0.7
0.20
0.20
1.00
0.0
1.0
2000
200
1.00
1.00
0.00
200
20
7
7
<1>
<1>
60.0
60.0
<4>
<4>
200.0
200.0
60.0
60.0
<4>
<4>
3.0
3.0
<4>
<4>
16.0
12.0
1.5
0.5
<4>
<4>
12.0
2.5
0.0
0.0
0.0
0.0
0.0
0.0
1
1
1.00
0.30
0.65
1.00
1.00
2.50
.Refer to
100
2
<3>
<3>
<3>
<3>