5.10 o: Operator Related Settings
d1-01 to d1-17: Frequency References
n
o1-05: LCD Contrast Control
Note:
Parameter available in drive software versions PRG: 1022 and later.
Sets the brightness of the optional LCD operator. The lower the setting, the brighter the LCD contrast. The higher the
setting, the darker the LCD contrast.
No.
o1-05
n
o1-10: User-Set Display Units Maximum Value
Determines the display value that is equal to the maximum output frequency. The decimal number is defined by parameter
o1-11.
Note:
This setting changes automatically when o1-03 is changed. o1-10 can only be adjusted when o1-03 is set to 3.
No.
o1-10
n
o1-11: User-Set Display Units Decimal Display
Determines the number of digits for user-set display if o1-03 is set to 3. The setting value is equal to the number of decimal
places. The maximum display value is defined by o1-10.
Note:
This setting changes automatically when o1-03 is changed. o1-11 can only be adjusted when o1-03 is set to 3.
No.
o1-11
u

o2: Operator Key Selections

These parameters determine the functions assigned to the operator keys.
n
o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching between
LOCAL and REMOTE.
No.
o2-01
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCAL
is selected, the LED indicator on the LO/RE key will light up.
WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already applied when switching from
LOCAL mode to REMOTE mode when b1-07 = 1, resulting in death or serious injury. Be sure all personnel are clear of rotating machinery
and electrical connections prior to switching between LOCAL mode and REMOTE mode.
n
o2-02: STOP Key Function Selection
Selects if the STOP key on the digital operator can be used to stop the operation when the drive is controlled from a remote
source (i.e., not from digital operator).
No.
o2-02
Setting 0: Disabled
The STOP key has no function when the drive is controlled by a source other than the digital operator. The drive can only
be stopped from the Run command source that has been selected.
Setting 1: Enabled
The STOP key can be used to terminate the operation, even if the Run command source is not assigned to the digital
operator. If operation has been interrupted by pressing the STOP key, the Run command must be cycled to restart the drive.
236
Name
LCD Contrast Control
Name
User-Set Display Units Maximum Value
Name
User-Set Display Units Decimal Display
Name
LO/RE Key Function Selection
Name
STOP Key Function Selection
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Setting Range
0 to 5
Setting Range
Determined by
1 to 60000
Setting Range
Determined by
0 to 3
Setting Range
0 or 1
Setting Range
0 or 1
Default
3
Default
o1-03
Default
o1-03
Default
1
Default
1