U: Monitors - YASKAWA V1000 Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
Motor Selection
T1-00
1/2
Auto-Tuning Mode
T1-01
Selection
T1-02
Motor Rated Power
T1-03
Motor Rated
<4>
Voltage
Motor Rated
T1-04
Current
Motor Base
T1-05
Frequency
Number of Motor
T1-06
Poles
T1-07
Motor Base Speed
T1-11
Motor Iron Loss
<1> The available tuning methods depend on control mode. Select values 2 or 3 in V/f Control, 0 or 2 in OLV control, and 2 for Motor 2 control.
<2> Setting range varies depending on drive software version.
PRG: 1016 and later: 0.03 to 650.00 kW
PRG: 1015 and earlier: 0.00 to 650.00 kW
<3> Default setting value is dependent on parameter o2-04, Drive Model Selection.
<4> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<5> Regional default settings:
Setting 60.0 Hz: Japan (Model code: CIMR-VAoA) and Asia (Model code: CIMR-VToA)
Setting 50.0 Hz: China (Model code: CIMR-VBoA)
<6> Regional default settings:
Setting 1750 r/min: Japan (Model code: CIMR-VAoA) and Asia (Model code: CIMR-VToA)
Setting 1450 r/min: China (Model code: CIMR-VBoA)
u

U: Monitors

Monitor parameters allow the user to view drive status, fault information, and other information about drive operation.
No.
Name
U1-01
Frequency Reference
U1-02
Output Frequency
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
Selects which set of motor parameters are used and set during
Auto-Tuning. If Motor 2 selection (H1-oo = 16) is not selected,
this parameter will not be displayed.
1: Motor 1 (sets E1-oo, E2-oo)
2: Motor 2 (sets E3-oo, E4-oo. This selection is not displayed
if motor 2 has not been selected.)
Selects the Auto-Tuning mode.
0: Rotational Auto-Tuning
2: Stationary Auto-Tuning for Line-to-Line Resistance
3: Rotational Auto-Tuning for V/f Control (necessary for Energy
Savings and Speed Estimation type Speed Search)
Sets the motor rated power in kilowatts (kW).
Note: If motor power is given in horsepower, power in kW can
be calculated using the following formula: kW = HP x 0.746.
Sets the motor rated voltage in volts (V).
Sets the motor rated current in amperes (A).
Sets the base frequency of the motor in Hertz (Hz).
Sets the number of motor poles.
Sets the base speed of the motor in revolutions per minute r/min
(RPM).
Provides the iron loss for determining the Energy Saving
coefficient.
The value set to E2-10 (motor iron loss) when the power is cycled.
If T1-02 is changed, an initial value valid for the selected capacity
will be shown.
Description
U1: Operation Status Monitors
Use U1 monitors to display the operation status of the drive.
Monitors the frequency
Displays the output frequency. Display units are
determined by o1-03.
B.2 Parameter Table
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
1, 2
1
A A −
2 or 3 in
V/f
0, 2, 3
0 or 2 in
A A −
<1>
OLV
2 in
Motor 2
<2>
<3>
A A −
0.0 to
200.0 V A A −
255.5
10 to
200% of
<3>
A A −
drive rated
current
0.0 to
<5>
A A −
400.0
2 to 48
4
A A −
<6>
0 to 24000
A A −
14 W
A −
These values differ depending on the
0 to 65535
motor code value and motor
parameter settings.
Control
Mode
Analog Output
Unit
Level
V/
f
10 V: Max
0.01
A A A
frequency
Hz
10 V: Max
0.01
A A A
frequency
Hz
Addr.
Pg.
Hex
700
104
701
104
702
104
703
104
704
104
705
105
706
105
707
105
70B
105
Addr.
O
Hex
P
L
M
V
40
B
41
371