B.2 Parameter Table
H2-oo
Function
Setting
37
During Frequency Output
38
Drive Enable
39
Watt Hour Pulse Output
3C
LOCAL/REMOTE Status
3D
Speed Search
3E
PID Feedback Loss Low
3F
PID Feedback Loss High
4A
KEB Operation
4B
Short-Circuit Brake
4C
During Fast-stop
4D
oH Pre-alarm Time Limit
4E
Braking Transistor Fault (rr)
<1>
4F
Braking Resistor Overheat
<1>
(oH)
90 to 92
DWEZ Digital Outputs 1 to 3 Reserved for DWEZ digital output functions.
H2 Parameter Functions
100 to 192
Reversed Output Switching of
0 to 92
<1> Available in drive software versions PRG: 1016 and later.
No.
Name
Terminal A1 Signal Level
H3-01
Selection
Terminal A1 Function
H3-02
Selection
H3-03
Terminal A1 Gain Setting
<2>
H3-04
Terminal A1 Bias Setting
<2>
Terminal A2 Signal Level
H3-09
Selection
Terminal A2 Function
H3-10
Selection
H3-11
Terminal A2 Gain Setting
<2>
H3-12
Terminal A2 Bias Setting
<2>
354
H2 Multi-Function Digital Output Settings
Open: No frequency output from drive if stopped, with baseblock, with DC injection
braking during initial excitation, or with short-circuit braking.
Closed: Drive is outputting a frequency
Closed: Multi-function input closes (H1-oo = 6A)
Output units are determined by H2-06, outputs 200 ms pulse for each incremented
kWh count.
Closed: LOCAL
Open: REMOTE
Closed: Speed search is being executed.
Closed: PID Feedback Loss Low.
PID feedback value is below the level set to b5-13 for longer than the time set in
b5-14.
Closed: PID Feedback Loss High.
PID feedback value exceeds the level set to b5-36 for longer than the time set to
b5-37.
Closed: KEB is being performed.
Closed: Short-Circuit Braking is active.
Closed: Fast-stop command is entered
Closed: oH Pre-alarm time limit is passed.
Closed: The built-in dynamic braking transistor failed.
Closed: The dynamic braking resistor has overheated.
Reverse the output switching of the multi-function output functions. Set the last two
digits of 1oo to reverse the output signal of that specific function.
Examples:
Setting "108" reverses the output of "During baseblock," which is setting value 08.
Setting "14A" reverses the output of "During KEB operation", which is setting "4A".
Description
H3: Analog Inputs
Use H3 parameters to set the multi-function analog input terminals.
Sets the input level for terminal A1.
0: 0 to +10 V (lower limit)
1: 0 to +10 V (no lower limit)
Sets the function of terminal A1.
When terminal A1 is not used or is used as a through
terminal, this parameter must be set to "F".
Sets the level of the input value selected in H3-02 when 10
V is input at terminal A1.
Sets the level of the input value selected in H3-02 when 0
V is input at terminal A1.
Sets the input signal level for terminal A2.
0: 0 to +10 V (with lower limit)
1: 0 to +10 V (no lower limit)
2: 4 to 20 mA
3: 0 to 20 mA
Sets the function of terminal A2.
When terminal A2 is not used or is used as a through
terminal, this parameter must be set to "F".
Sets the level of the input value selected in H3-10 when 10
V (20 mA) is input at terminal A2.
Sets the level of the input value selected in H3-10 when 0
V (0 or 4 mA) is input at terminal A2.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
Range
0, 1
0 to 31
<1>
-999.9 to
999.9
-999.9 to
999.9
0 to 3
Use DIP switch S1 to set input terminal A2 for
a current or a voltage input signal.
0 to 31
<1>
-999.9 to
999.9
-999.9 to
999.9
Control
Mode
Pg.
O
V/
P
L
f
M
V
O O O
193
O O O
194
O O O
194
O O O
194
O O O
194
O O O
194
O O O
194
O O O
194
− O
194
O O O
194
O O O
194
O O O
194
O O O
194
O O O
194
O O O
195
Control
Mode
Addr.
Def.
Pg.
O
Hex
V/
P
L
f
M
V
0
A A A
410
195
0
A A A
434
196
100.0
A A A
411
196
%
0.0% A A A
412
196
2
A A A
417
197
0
A A A
418
198
100.0
A A A
419
198
%
0.0% A A A