n
E5-02: Motor Rated Power (PM OLV)
Sets the rated power of the motor.
No.
E5-02
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-03: Motor Rated Current (PM OLV)
Sets the motor rated current in amps.
No.
E5-03
Note:
1. Display is in the following units: BA0001 to BA0018, 2A0001 to 2A0040, and 4A0001 to 4A0023: 0.01 A units.
2A0056 to 2A0069, 4A0031 to 4A0038: 0.1 A units.
2. This parameter is not reset when the drive is initialized using A1-03.
n
E5-04: Number of Motor Poles (PM OLV)
Sets the number of motor poles.
No.
E5-04
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-05: Motor Stator Resistance (PM OLV)
Set the resistance for each motor phase (not line-to-line resistance). When measuring the resistance manually make sure
to enter the resistance of one phase into E5-05.
No.
E5-05
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-06: Motor d Axis Inductance (PM OLV)
Sets the d axis inductance in units of 0.01 mH. Contact the motor manufacturer for d-axis inductance. If an LCR meter is
available, enter half the value of the measurement taken.
No.
E5-06
Note:
This parameter is not reset when the drive is initialized using A1-03.
n
E5-07: Motor q Axis Inductance (PM OLV)
Sets the q axis inductance in units of 0.01 mH. Contact the motor manufacturer for d-axis inductance. If an LCR meter is
available, enter half the value of the measurement taken.
No.
E5-07
Note:
This parameter is not reset when the drive is initialized using A1-03.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
0 0 0 0
0: Pico Motor
(SMRA Series)
1: Derated Torque for IPM
Motors
(SSR 1 Series)
Figure 5.44 PM Motor Code
Parameter Name
Motor Rated Power
Parameter Name
Motor Rated Current
Parameter Name
Number of Motor Poles
Parameter Name
Motor Stator Resistance
Parameter Name
Motor d Axis Inductance
Parameter Name
Motor q Axis Inductance
5.5 E: Motor Parameters
Motor Voltage Class
and Capacity
0: 1800 r/min Series
1: 3600 r/min Series
2: 1750 r/min Series
3: 1450 r/min Series
4: 1150 r/min Series
F: Special Motor
Setting Range
0.10 to 18.50 kW
Setting Range
10 to 200% of drive rated
current
Setting Range
2 to 48
Setting Range
0.000 to 65.000 Ω
Setting Range
0.00 to 300.00 mH
Setting Range
0.00 to 600.00 mH
Default
Depending on
E5-01
Default
Depending on
E5-01
Default
Depending on
E5-01
Default
Depending on
E5-01
5
Default
Depending on
E5-01
Default
Depending on
E5-01
171