B.2 Parameter Table
No.
Name
Motor d-Axis Current at
U2-17
Previous Fault
U3-01
Most Recent Fault
U3-02
2nd Most Recent Fault
U3-03
3rd Most Recent Fault
U3-04
4th Most Recent Fault
U3-05
5th Most Recent Fault
U3-06
6th Most Recent Fault
U3-07
7th Most Recent Fault
U3-08
8th Most Recent Fault
U3-09
9th Most Recent Fault
U3-10
10th Most Recent Fault
Cumulative Operation Time
U3-11
at Most Recent Fault
Cumulative Operation Time
U3-12
at 2nd Most Recent Fault
Cumulative Operation Time
U3-13
at 3rd Most Recent Fault
Cumulative Operation Time
U3-14
at 4th Most Recent Fault
Cumulative Operation Time
U3-15
at 5th Most Recent Fault
Cumulative Operation Time
U3-16
at 6th Most Recent Fault
Cumulative Operation Time
U3-17
at 7th Most Recent Fault
Cumulative Operation Time
U3-18
at 8th Most Recent Fault
Cumulative Operation Time
U3-19
at 9th Most Recent Fault
Cumulative Operation Time
U3-20
at 10th Most Recent Fault
U4-01
Accumulated Operation
<7>
Time
U4-02
Number of Run Commands
U4-03
Cooling Fan Operation Time
<5> <8>
374
Description
Displays the d-axis current for the motor at the previous
fault.
U3: Fault History
Use U3 monitors to display fault data.
Displays the most recent fault.
Displays the second most recent fault.
Displays the third most recent fault.
Displays the fourth most recent fault.
Displays the fifth most recent fault.
Displays the sixth most recent fault.
Displays the seventh most recent fault.
Displays the eighth most recent fault.
Displays the ninth most recent fault.
Displays the tenth most recent fault.
Displays the cumulative operation time at the most recent
fault.
Displays the cumulative operation time at the second most
recent fault.
Displays the cumulative operation time at the third most
recent fault.
Displays the cumulative operation time at the fourth most
recent fault.
Displays the cumulative operation time at the fifth most
recent fault.
Displays the cumulative operation time at the sixth most
recent fault.
Displays the cumulative operation time at the seventh most
recent fault.
Displays the cumulative operation time at the eighth most
recent fault.
Displays the cumulative operation time at the ninth most
recent fault.
Displays the cumulative operation time at the tenth most
recent fault.
U4: Maintenance Monitors
Use U4 monitors to display drive maintenance information.
Displays the cumulative operation time of the drive. The
value for the cumulative operation time counter can be
reset in parameter o4-01. Use parameter o4-02 to
determine if the operation time should start as soon as the
power is switched on or only while the run command is
present. The maximum number displayed is 99999, after
which the value is reset to 0.
Displays the number of times the run command is entered.
Reset the number of run commands using parameter o4-13.
This value will reset to 0 and start counting again after
reaching 65535.
Displays the cumulative operation time of the cooling fan.
The default value for the fan operation time is reset in
parameter o4-03. This value will reset to 0 and start
counting again after reaching 99999.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Analog Output
Level
No signal output
avail.
<3>
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
<4>
Control
Mode
Addr.
Unit
O
Hex
V/
P
L
f
M
V
0.10
− A A
7E2
%
90
A A A
(800)
91
A A A
(801)
92
A A A
(802)
93
A A A
(803)
A A A
804
A A A
805
A A A
806
A A A
807
A A A
808
A A A
809
94
1 h
A A A
(80A)
95
1 h
A A A
(80B)
96
1 h
A A A
(80C)
97
1 h
A A A
(80D)
1 h
A A A
80E
1 h
A A A
80F
1 h
A A A
810
1 h
A A A
811
1 h
A A A
812
1 h
A A A
813
1 h
A A A
4C
A A A
75
1 h
A A A
67

Hide quick links: