YASKAWA V1000 Technical Manual page 368

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
User Parameter Default
o2-03
Value
o2-04
Drive Model Selection
<4>
Frequency Reference Setting
o2-05
Method Selection
Operation Selection when
o2-06
Digital Operator is
Disconnected
Motor Direction at Power Up
o2-07
when Using Operator
o2-09
Use o3 parameters to Read, Copy and Verify the parameter settings to and from the drive.
o3-01
Copy Function Selection
o3-02
Copy Allowed Selection
Accumulated Operation
o4-01
Time Setting
Accumulated Operation
o4-02
Time Selection
Cooling Fan Operation Time
o4-03
Setting
Capacitor Maintenance
o4-05
Setting
DC Bus Pre-Charge Relay
o4-07
Maintenance Setting
o4-09
IGBT Maintenance Setting
o4-11
U2, U3 Initialization
368
Description
Allows storing of parameter settings as a User Initialization
Selection (value 1110 for A1-03). The value returns to 0 after
entering 1 or 2.
0: No Change
1: Set Defaults - Saves current parameter settings as user
initialization.
2: Clear All - Clears the currently saved user initialization.
Sets the drive model.
This parameter only needs to be set when installing a new
control board. Do not change for other reason.
Selects if the ENTER key must be pressed when inputting
the frequency reference by the operator keypad.
0: Data/Enter key must be pressed to enter a frequency
reference.
1: Data/Enter key is not required.
The output frequency changes immediately when the
reference is changed by the UP or DOWN keys on the digital
operator. The ENTER key does not need to be pressed.
Sets drive action when the digital operator is removed in
LOCAL mode or with b1-02 = 0.
0: The drive will continue operation
1: The drive will trigger a fault (oPr) and the motor will coast
to stop
0: Forward
1: Reverse
This parameter requires that drive operation be assigned to
the digital operator.
Factory use.
o3: Copy Function
0: Copy select
1: INV → OP READ (Read parameters from the drive,
saving them onto the digital operator.)
2: OP → INV WRITE (Copy parameters from the digital
operator, writing them to the drive.)
3: OP → INV VERIFY (Verify parameter settings on the
drive to check if they match the data saved on the operator.)
To read the drive parameter settings into the digital operator,
set o3-02 to 1 (to allow reading).
Locks the READ operation to prevent accidental overwriting
of the data stored in the LED operator.
0: READ operation prohibited
1: READ operation allowed
o4: Maintenance Period
Use o4 parameters to perform maintenance.
Sets the value for the cumulative operation time of the drive
in units of 10 h.
Determines, how the cumulative operation time (U4-01) is
counted.
0: Logs power-on time
1: Logs operation time when the drive output is active
(output operation time).
Sets the value of the fan operation time monitor U4-03 in
<6>
units of 10 h.
Sets the value of the capacitor maintenance time monitor
U4-05.
Sets the value of the Soft Charge Bypass Relay Maintenance
monitor U4-06.
Sets the value of the IGBT Maintenance monitor U4-07.
0: U2-oo and U3-oo monitor data are not reset when the
drive is initialized using A1-03.
1: U2-oo and U3-oo monitor data are reset when the
drive is initialized using A1-03. (The value of o4-11 is
automatically returned to 0.)
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0 to 2
0
A A A
<5>
0 to FF
A A A
0, 1
0
A A A
0, 1
0
A A A
0, 1
0
A A A
0 to 3
0
A A A
0, 1
0
A A A
0 to 9999
0
A A A
0, 1
0
A A A
0 to 9999
0
A A A
0 to 150
0%
A A A
0 to 150
0%
A A A
0 to 150
0%
A A A
0, 1
0
A A A
Addr.
Pg.
Hex
507
237
508
237
509
237
50A
237
527
238
515
516
50B
238
50C
239
50E
239
51D
239
523
239
525
239
510
239

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents