YASKAWA V1000 Technical Manual page 339

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
C6-01
Drive Duty Selection
Carrier Frequency
C6-02
Selection
Carrier Frequency Upper
C6-03
Limit
Carrier Frequency Lower
C6-04
Limit
Carrier Frequency
C6-05
Proportional Gain
<1> Parameter can be changed during run.
<2> Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. When C1-10 = 0 (units of 0.01 seconds), the setting
range becomes 0.00 to 600.00 seconds.
<3> Available in drive software versions PRG: 1020 and later.
<4> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 0-V/f Control.
<5> Parameter cannot be changed during run when parameter A1-02 = 5-PM OLV Control.
<6> Default setting value is dependent on parameter A1-02, Control Method Selection. The value shown is for A1-02 = 2-OLV control.
<7> Setting range is determined by the drive software version.
PRG: 1020 and later: 1 to B; F
PRG: 1018 and earlier: 1 to A; F
<8> Default setting value is dependent on parameters o2-04, Drive Model Selection, A1-02, Control Method Selection and C6-01, Drive Duty
Selection.
<9> Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
Selects the load rating for the drive.
0: Heavy Duty (HD) for constant torque applications.
1: Normal Duty (ND) for variable torque applications.
This setting affects the Rated output current and overload
tolerance of the drive.
Selects the carrier frequency
1 : 2.0 kHz
2 : 5.0 kHz
3 : 8.0 kHz
4 : 10.0 kHz
5 : 12.5 kHz
6 : 15.0 kHz
7 : Swing PWM1 (Audible sound 1)
8 : Swing PWM2 (Audible sound 2)
9 : Swing PWM3 (Audible sound 3)
A : Swing PWM4 (Audible sound 4)
B: Leakage Current Rejection PWM
C to E: No setting possible
F : User defined (determined by C6-03 through C6-05)
Note: Set C6-02 to F before setting C6-03.
Open Loop Vector: C6-03 defines the fixed carrier
frequency if C6-02 = F.
V/f Control: C6-03 and C6-04 set upper and lower limits
for the carrier frequency.
carrier frequency
C6-03
C6-04
output frequency
× (C6-05) × K
E1-04
max output
frequency
The coefficient K depends on C6-03:
C6-03 ≥ 10.0 kHz: K = 3
10.0 kHz > C6-03 ≥ 5.0 kHz: K = 2
5.0 kHz > C6-03: K = 1
When C6-05 ≤ 6, C6-04 is disabled (makes the carrier
frequency C6-03 value).
Sets the relationship of output frequency to carrier
frequency when C6-02 = F.
Range
0, 1
<7>
<3>
1.0 to 15.0
output
1.0 to 15.0
frequency
00 to 99
B.2 Parameter Table
Control
Mode
Addr.
Def.
Pg.
O
Hex
V/
P
L
f
M
V
1
S
S
S
223
150
<8>
S
S
S
224
151
<9>
A A A
225
151
<9>
A
-
-
226
151
<9>
A
-
-
227
151
339
B