3.5 Protective Covers
u

IP20/NEMA Type 1 Front and Bottom Cover Removal and Installation

n
Removing the Protective Covers on an IP20/NEMA Type 1 Design
1.
Loosen the screw on the front cover to remove the front cover.
2.
Loosen the screw on the terminal cover to remove the terminal cover and expose the conduit bracket.
A – Conduit bracket
3.
Loosen two screws attaching the conduit bracket to remove.
A –Conduit bracket
n
Reattaching the Protective Covers
Pass power wiring and control signal wiring through the exit holes on the bottom of the conduit bracket of the drive. Place
power wiring and control signal wiring in separate conduits. Properly connect all wiring after installing the drive and
connecting other devices. Reattach all protective covers when wiring is complete.
A –Pass power wiring and control signal wiring through different exit holes at the
Figure 3.12 Reattach the Protective Covers and Conduit Bracket on an IP20/NEMA Type 1 Drive
54
Figure 3.9 Remove the Front Cover on an IP20/NEMA Type 1 Drive
Figure 3.10 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive
A
Figure 3.11 Remove the Conduit Bracket on an IP20/NEMA Type 1 Drive
bottom of the drive.
A
B
B – Terminal cover
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
A

Hide quick links: