YASKAWA V1000 Technical Manual page 356

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
H4-02
Multi-Function Analog
<2>
Output Terminal AM Gain
H4-03
Multi-Function Analog
<2>
Output Terminal AM Bias
The settings for MEMOBUS/Modbus communications become effective when the drive is restarted.
H5-01
Drive Node Address
<3>
Communication Speed
H5-02
Selection
Communication Parity
H5-03
Selection
Stopping Method After
H5-04
Communication Error
Communication Fault
H5-05
Detection Selection
H5-06
Drive Transmit Wait Time
H5-07
RTS Control Selection
H5-09
CE Detection Time
Unit Selection for
H5-10
MEMOBUS/Modbus
Register 0025H
Communications ENTER
H5-11
Function Selection
Run Command Method
H5-12
Selection
Pulse Train Input Terminal
H6-01
RP Function Selection
H6-02
Pulse Train Input Scaling
<2>
356
Description
Sets terminal AM output gain.
Maximum output voltage is 10 V.
Sets terminal AM output bias.
H5: MEMOBUS/Modbus Communications
Use H5 Parameters to connect the drive to a MEMOBUS/Modbus network.
Selects drive station node number (address) for
MEMOBUS/Modbus terminals R+, R-, S+, S-. Cycle power
for the setting to take effect.
Selects the baud rate for MEMOBUS/Modbus terminals R
+, R-, S+ and S-. Cycle power for the setting to take effect.
0 : 1200 bps
1 : 2400 bps
2 : 4800 bps
3 : 9600 bps
4 : 19200 bps
5 : 38400 bps
6 : 57600 bps
7 : 76800 bps
8 : 115200 bps
Selects the communication parity for MEMOBUS/Modbus
terminals R+, R-, S+ and S-. Cycle power for the setting to
take effect.
0: No parity
1: Even parity
2: Odd parity
Selects the stopping method when a communication time-
out fault (CE) is detected.
0: Ramp to stop
1: Coast to stop
2: Fast-stop
3: Alarm only
Enables or disables the communications time-out fault (CE)
detection.
0: Disabled
1: Enabled - If communication is lost for more than two
seconds, a CE fault will occur.
Set the wait time between receiving and sending data.
Selects "request to send" (RTS) control:
0: Disabled - RTS is always on.
1: Enabled - RTS turns on only when sending.
Sets the time required to detect a communications error.
Adjustment may be need when networking several drives.
Selects the units used for MEMOBUS/Modbus register
0025H (Output Voltage Reference Monitor).
0: 0.1 V units
1: 1 V units
Select the function for the enter command that saves
parameter data to the drive.
0: Parameter changes are activated when ENTER command
is entered.
1: Parameter changes are activated immediately without
ENTER command (compatible with Varispeed VS606-V7).
0: FWD/STOP, REV/STOP Method
1: RUN/STOP, FWD/REV Method
H6: Pulse Train Input/Output
Use H6 parameters to configure Pulse Train I/O operation.
Selects pulse train input function.
0: Frequency reference
1: PID feedback value
2: PID setpoint value
3: V/f Control with Simple PG Feedback (can be set only
when using motor 1 in V/f Control)
Sets the terminal RP input signal frequency that is equal to
100% of the value selected in H6-01.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
-999.9 to
100.0
S
S
S
999.9
%
-999.9 to
0.0% A A A
999.9
0 to 20 H
1F
A A A
0 to 8
3
A A A
0 to 2
0
A A A
0 to 3
3
A A A
0, 1
1
A A A
5 to 65
5 ms A A A
0, 1
1
A A A
0.0 to
2.0 s A A A
10.0 s
0, 1
0
A A A
0, 1
1
A A A
0, 1
0
A A A
0 to 3
0
A A A
1440
<4>
A A A
Hz
Addr.
Pg.
Hex
41E
200
41F
200
425
409
426
409
427
409
428
409
429
410
42A
410
42B
410
435
410
436
410
43C
410
43D
411
42C
201
42D
201