Changing Parameter Settings Or Values - YASKAWA V1000 Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

Frequency reference
appears when powered up
<2>
Parameter Display
u

Changing Parameter Settings or Values

This example explains changing C1-01 (Acceleration Time 1) from 10.0 seconds (default) to 20.0 seconds.
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key until the Setup Mode Screen appears.
3.
Press the
key to view the parameter setting display.
4.
Scroll through parameters by pressing the
Press
to view the current setting value (10.0). (Number farthest to the left
5.
flashes)
6.
Press
until the desired number is selected. ("1" flashes)
7.
Press the
key and enter 0020.0.
8.
Press
and the drive will confirm the change.
9.
The display automatically returns to the screen shown in Step 4.
10. Press the
key until back at the initial display.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Press until
STOP
appears
STOP
LED Operator
STOP
<1> Pressing ENTER from APPL navigates to the Application
Preset setting display. When the set value is changed, the
STOP
parameter is changed to the optimum value for each
application. It is set to 0 (General-purpose) prior to shipment.
<2> Move to the right to change parameter settings. Scroll
down to view and check settings in the Setup Mode.
<3> To return to the Top Menu, press
STOP
other parameters, press
Figure 4.5 Setup Group Example
Step
key until C1-01 appears.
4.3 The Drive and Programming Modes
<1>
Application
Preset
Control Circuit
Select digit
Terminal
to edit
<3>
Parameter Display
STOP
. To view or edit
and
.
Display/Result
85
4

Hide quick links:

Advertisement

Table of Contents
loading