YASKAWA V1000 Technical Manual page 343

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
E2-01
Motor Rated
<8>
Current
E2-02
Motor Rated Slip
Motor No-Load
E2-03
Current
Number of Motor
E2-04
Poles
Motor Line-to-Line
E2-05
Resistance
Motor Leakage
E2-06
Inductance
Motor Iron-Core
E2-07
Saturation
Coefficient 1
Motor Iron-Core
E2-08
Saturation
Coefficient 2
Motor Mechanical
E2-09
Loss
Motor Iron Loss for
E2-10
Torque
Compensation
Motor Rated
E2-11
Output
Motor Iron-Core
E2-12
Saturation
Coefficient 3
Motor 2 Control
E3-01
Method
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
Sets the motor nameplate full load current in amperes (A).
Automatically set during Auto-Tuning.
Note: Set E2-03 (Motor No-Load Current) before making
changes to E2-01. An oPE01 error will be triggered if
E2-01 < E2-03.
Sets the motor rated slip in Hertz.
Automatically set during rotational Auto-Tuning.
Sets the magnetizing current of the motor in Ampere.
Automatically set during rotational Auto-Tuning.
Note: Set E2-03 (Motor No-Load Current) before making
changes to E2-01. An oPE01 error will be triggered if
E2-01 < E2-03.
Sets the number of motor poles. Automatically set during
Auto-Tuning.
Sets the phase-to-phase motor resistance in ohms.
Automatically set during Auto-Tuning.
Sets the voltage drop due to motor leakage inductance as a
percentage of motor rated voltage.
Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 50% of
magnetic flux. Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 75% of
magnetic flux. Automatically set during Auto-Tuning.
Sets the motor mechanical loss as a percentage of motor
rated power (kW). Adjust in the following circumstances:
When there is a large amount of torque loss due to motor
bearing friction.
When there is a large amount of torque loss.
Sets the motor iron loss in watts (W).
Sets the motor rated power in kilowatts (kW).
Automatically set during Auto-Tuning. (1 HP = 0.746 kW).
Set to the motor iron saturation coefficient at 130% of
magnetic flux.
Automatically set during rotational Auto-Tuning.
E3: Motor 2 V/f Characteristics
Use E3 parameters to set the V/f pattern for a second motor.
0: V/f Control
2: Open Loop Vector (OLV)
B.2 Parameter Table
Control
Mode
Range
Def.
V/f O
LV
10 to 200%
of drive
rated
<10>
S
S
current
<9>
0.00 to
<10>
A
A
20.00
0 to less
<10>
A
A
than E2-01
2 to 48
4 poles
A
A
0.000 to
65.000
<10>
A
A
<11>
0.0 to 40.0
<10>
A
A
0.00 to
0.50
A
0.50
E2-07 to
0.75
A
0.75
0.0 to 10.0
0.0%
A
<10>
0 to 65535
A
0.40 kW
0.00 to
S
S
<6>
650.00
1.30 to
1.30
A
5.00
0 or 2
0
A
A
Addr. Hex Pg.
PM
30E
165
30F
166
310
166
311
166
312
166
313
166
314
166
315
167
316
167
317
167
318
167
328
167
319
167
B
343