YASKAWA V1000 Technical Manual page 460

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

E.3 User Setting Table
No.
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-09
Terminal A2 Signal Level Selection
H3-10
Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
Frequency Reference (Current) Terminal A2
H3-12
Input Bias
H3-13
Analog Input Filter Time Constant
H3-14
Analog Input Terminal Enable Selection
H3-16
Terminal A1 Offset
H3-17
Terminal A2 Offset
Multi-Function Analog Output (Terminal
H4-01
AM Monitor Selection)
Multi-Function Analog Output (Terminal
H4-02
AM Output Gain)
Multi-Function Analog Output (Terminal
H4-03
AM Output Bias)
H5-01
Drive Node Address
H5-02
Communication Speed Selection
H5-03
Communication Parity Selection
Stopping Method After Communication
H5-04
Error
H5-05
Communication Fault Detection Selection
H5-06
Drive Transmit Wait Time
H5-07
RTS Control Selection
H5-09
CE Detection Time
Unit Selection for MEMOBUS/Modbus
H5-10
Register 0025H
H5-11
Communications ENTER Function Selection
H5-12
Run Command Method Selection
(Terminal RP) Pulse Train Input Function
H6-01
Selection
H6-02
Pulse Train Input Scaling
H6-03
Pulse Train Input Gain
H6-04
Pulse Train Input Bias
H6-05
Pulse Train Input Filter Time
H6-06
(Terminal MP) Pulse Train Monitor Selection
H6-07
Pulse Train Monitor Scaling
L1-01
Motor Overload Protection Selection
L1-02
Motor Overload Protection Time
Motor Overheat Alarm Operation Selection
L1-03
(PTC input)
Motor Overheat Fault Operation Selection
L1-04
(PTC input)
Motor Temperature Input Filter Time (PTC
L1-05
input)
Continuous Electrothermal Operation
L1-13
Selection
L1-22
Leakage Current Filter Time Constant 1
L1-23
Leakage Current Filter Time Constant 2
L2-01
Momentary Power Loss Operation Selection
L2-02
Momentary Power Loss Ride-Thru Time
Momentary Power Loss Minimum Baseblock
L2-03
Time
Momentary Power Loss Voltage Recovery
L2-04
Ramp Time
L2-05
Undervoltage Detection Level (Uv)
L2-06
KEB Deceleration Time
460
Name
Setting
User
No.
L2-07
Momentary Power Loss Ride-Thru Time
L2-08
Minimum Frequency Gain at KEB Start
L2-11
Desired DC Bus Voltage During KEB
Stall Prevention Selection during
L3-01
Acceleration
L3-02
Stall Prevention Level during Acceleration
L3-03
Stall Prevention Limit during Acceleration
Stall Prevention Selection during
L3-04
Deceleration
L3-05
Stall Prevention Selection during Run
L3-06
Stall Prevention Level during Run
L3-11
ov Suppression Function Selection
Overvoltage Suppression and Deceleration
L3-17
Stall (Desired DC Bus Voltage during Motor
Stall)
L3-20
Main Power Circuit Voltage Adjustment Gain
L3-21
Accel/Decel Rate Calculation Gain
Deceleration Time at Stall Prevention during
L3-22
Acceleration
Automatic Reduction Selection for Stall
L3-23
Prevention during Run
Motor Acceleration Time for Inertia
L3-24
Calculations
L3-25
Load Inertia Ratio
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
Frequency Reference Loss Detection
L4-05
Selection
L4-06
Frequency Reference at Reference Loss
L4-07
Frequency Detection Conditions
L4-08
Speed Agreement Detection Conditions
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Operation Selection
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
L6-08
Mechanical Weakening Detection Operation
Mechanical Weakening Detection Speed
L6-09
Level
L6-10
Mechanical Weakening Detection Time
L6-11
Mechanical Weakening Detection Start Time
L7-01
Forward Torque Limit
L7-02
Reverse Torque Limit
L7-03
Forward Regenerative Torque Limit
L7-04
Reverse Regenerative Torque Limit
L7-06
Torque Limit Integral Time Constant
Torque Limit Control Method Selection
L7-07
during Accel/Decel
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual