B.2 Parameter Table
No.
Name
Main Power Circuit Voltage
L3-20
Adjustment Gain
Accel/Decel Rate
L3-21
Calculation Gain
Deceleration Time at Stall
L3-22
Prevention during
Acceleration
Automatic Reduction
L3-23
Selection for Stall
Prevention during Run
Motor Acceleration Time for
L3-24
Inertia Calculations
L3-25
Load Inertia Ratio
Speed Agreement Detection
L4-01
Level
Speed Agreement Detection
L4-02
Width
Speed Agreement Detection
L4-03
Level (+/-)
Speed Agreement Detection
L4-04
Width (+/-)
Frequency Reference Loss
L4-05
Detection Selection
Frequency Reference at
L4-06
Reference Loss
Frequency Detection
L4-07
Conditions
L4-08
Speed Agreement Detection
<12>
Conditions
Number of Auto Restart
L5-01
Attempts
Auto Restart Operation
L5-02
Selection
360
Description
Sets the proportional gain used by KEB, Stall Prevention and
overvoltage suppression.
If ov or Uv1 occurs at the beginning of KEB deceleration,
slowly increase this setting by 0.1.
Sets the proportional gain used to calculate the deceleration
rate during KEB, ov suppression function and Stall
Prevention during deceleration (L3-04 = 2).
This parameter does not typically require adjustment.
Increase the value in steps of 1.0 if overcurrent and
overvoltage occur.
Sets the deceleration time used for Stall Prevention during
acceleration in Open Loop Vector Control for PM motors.
When set to 0, the drive decelerates at the normal
deceleration time.
0: Sets the Stall Prevention level throughout the entire
frequency range to the value in parameter L3-06.
1: Automatically lowers the Stall Prevention level in the
constant output range. The lower limit value is 40% of
L3-06.
Sets the time needed to accelerate the uncoupled motor at
rated torque from stop to the maximum frequency.
Setting the drive capacity to parameter o2-04 or changing
E2-11 will automatically set this parameter for a 4-pole
motor.
Sets the ratio between the motor and machine inertia.
L4: Frequency Detection
Use L4 parameters to configure frequency detection operation.
These parameters configure the multi-function output (H2-
oo = 2, 3, 4, 5) settings "Speed Agree 1", "User Set Speed
Agree 1", "Frequency Detection 1," and "Frequency
detection 2".
Parameter L4-01 sets the level while parameter L4-02 sets
the hysteresis for the Speed Detection Output Function.
These parameters configure the Multi-Function Output (H2-
oo = 13, 14, 15, 16) settings "Speed Agree 2", "User Set
Speed Agree 2", "Frequency Detection 3," or "Frequency
Detection 4".
Parameter L4-03 sets the level while parameter L4-04 sets
the hysteresis for the Speed Detection Output Function.
Sets operation when the frequency reference is lost
(reference drops 90% or more within 400 ms).
0: Stop - Drive will stop.
1: Run at L4-06 Level - Drive will run at the percentage set
in L4-06 of the frequency reference before loss.
Sets the frequency reference when a reference loss was
detected and L4-05 = 1. Reference will be: Fref = Fref at
time of loss x L4-06.
0: No detection during baseblock.
1: Detection always enabled.
0: Match speed with the soft-starter output
1: Match frequency reference and motor speed
Note: In V/f Control, the drive ignores the value set to L4-08
and refers to the soft-starter output to determine whether a
speed agree situation has been reached.
L5: Fault Reset
Use L5 parameters to configure Automatic Restart after fault.
Sets the counter for the number of times the drive attempts
to restart when one of the following faults occurs: GF, LF,
oC, oH1, ov, PF, rH, rr, oL1, oL2, oL3, oL4, STo, Uv1.
Parameter L5-05 determines the how the restart counter is
incremented.
When the drive operates without fault for 10 minutes, the
counter will be reset.
Sets fault contact (H2-oo = E) activation during automatic
restart attempts.
0: Fault output not active.
1: Fault output active during restart attempt.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0.00 to
1.00
A A A
5.00
0.00 to
1.00
A A A
200.00
0.0 to
0.0 s
− A
6000.0
0, 1
0
A A Α
<4>
0.001 to
<10>
A A A
10.000
<11>
0.0 to
1.0
A A A
1000.0
0.0 to
0.0
A A A
400.0
Hz
0.0 to
2.0
A A A
20.0
Hz
-400.0 to
0.0
A A A
+400.0
Hz
0.0 to
2.0
A A A
20.0
Hz
0, 1
0
A A A
0.0 to
80.0
A A A
100.0
%
0, 1
0
A A A
0, 1
0
A A A
0 to 10
0
A A A
0, 1
0
A A A
Addr.
Pg.
Hex
465
215
466
215
4F9
212
4FD
214
46E
216
46F
216
499
216
49A
216
49B
216
49C
216
49D
217
4C2
217
470
217
47F
217
49E
220
49F
220