B.6 Defaults by Drive Model and Duty Rating (ND/HD)
No.
Description
Model
o2-04
Drive Model Selection
C6-01
Normal/Heavy Duty
E2-11
(E4-11,
Motor rated power
T1-02)
b3-06
Speed Search current 1
Current Control Gain during Speed
b3-08
Search (Speed Estimation Type)
b8-04
Energy saving coefficient
C6-02
Carrier frequency
E2-01
(E4-01,
Motor rated current
T1-04)
E2-02
Motor rated slip
(E4-02)
E2-03
Motor no-load current
(E4-03)
E2-05
Motor line-to-line resistance
(E4-05)
E2-06
Motor leakage inductance
(E4-06)
E2-10
Motor Iron Loss
(E4-10)
E5-01
Motor Code
Momentary power loss ride-
L2-02
through time
Momentary power loss Baseblock
L2-03
time
Momentary power loss voltage
L2-04
recovery time
L2-05
Uv detection voltage
L3-24
Motor acceleration time
L8-02
Overheat alarm level
L8-09
Ground fault selection
L8-35
Installation Method Sel.
Carrier frequency reduction
L8-38
selection
n1-03
Hunting Prevention Time Constant
Speed Feedback Detection Control
n2-01
(AFR) Gain
386
Unit
2A0040
Hex
6B
HD
ND
0
1
kW
7.5
11.0
0.5
0.5
0.5
0.5
72.69
70.44
3
7
A
26.6
39.7
Hz
1.3
1.7
A
8.0
11.2
Ω
0.288
0.230
%
15.5
19.5
W
262
245
hex
FFFF
FFFF
s
1.0
1.0
s
0.8
0.9
s
0.3
0.3
V dc
190
190
s
0.175
0.265
°C
121
121
1
1
2
2
2
2
ms
10
10
1.50
1.50
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Default Settings
2A0056
6D
HD
ND
0
1
11.0
15.0
0.5
0.5
0.5
0.5
70.44
63.13
63.13
3
7
39.7
53
1.7
1.6
11.2
15.2
0.230
0.138
0.138
19.5
17.2
245
272
FFFF
FFFF
FFFF
2.0
2.0
0.9
1.0
0.3
0.3
190
190
0.265
0.244
0.244
120
120
1
1
2
2
2
2
10
10
1.50
1.50
2A0069
6E
HD
ND
0
1
15.0
18.5
0.5
0.5
0.5
0.5
57.87
3
7
53
65.8
1.6
1.67
15.2
15.7
0.101
17.2
15.7
272
505
FFFF
2.0
2.0
1.0
1.0
0.6
0.6
190
190
0.317
120
120
1
1
2
2
2
2
10
10
1.50
1.50