B.7 Parameters that Change with the Motor Code Selection
n
Drive Software Version PRG: 1018 and Later
Par.
Description
Motor Code
Voltage Class
E5-01
Rated Power
Rated Speed
E5-02 Motor Rated Power
E5-03 Motor Rated Current
E5-04 Motor Pole Number
Motor Winding
E5-05
Resistance
E5-06 d-Axis Inductance
E5-07 q-Axis Inductance
Induction Voltage
E5-09
mVs/rad
Constant 1
Induction Voltage
E5-24
Constant 2
Maximum Output
E1-04
Frequency
Maximum Output
E1-05
Voltage
E1-06 Base Frequency
Minimum Output
E1-09
Frequency
Motor Acceleration
L3-24
Time for Inertia
<1>
Calculations
d-Axis Current for
n8-49
High-Efficiency
Control
<1> Default setting value is dependent on parameter o2-04, Drive Model Selection.
400
Table B.20 200 V, 1150 rpm Type Yaskawa SSR1 Series Motor
Unit
1402
1403
200 Vac
200 Vac
0.4 kW
0.75 kW
r/min
1150
1150
kW
0.4
0.75
A
1.88
3.02
6
6
Ω
4.832
2.704
mH
48.68
32.31
mH
63.21
40.24
320.4
327.1
mV/(r/
0
0
min)
Hz
57.5
57.5
V
190
190
Hz
57.5
57.5
Hz
2.9
2.9
s
0.062
0.044
%
–8.8
–9.9
Default Settings
1405
1406
1408
200 Vac
200 Vac
200 Vac
1.5 kW
2.2 kW
3.7 kW
1150
1150
1150
1.5
2.2
3.7
6.00
8.85
14.27
6
6
6
1.114
0.511
0.412
19.22
12.15
7.94
24.38
15.35
11.86
364.4
344.4
357.5
0
0
0
57.5
57.5
57.5
190
190
190
57.5
57.5
57.5
2.9
2.9
2.9
0.08
0.09
0.067
–9.3
–10
–17.7
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
140A
140B
140D
200 Vac
200 Vac
200 Vac
5.5 kW
7.5 kW
11 kW
1150
1150
1150
5.5
7.5
11
20.21
26.67
39.9
6
6
6
0.303
0.165
0.113
11.13
6.59
4.96
14.06
8.55
6.12
430.8
391.5
384.4
0
0
0
57.5
57.5
57.5
190
190
190
57.5
57.5
57.5
2.9
2.9
2.9
0.072
0.088
0.073
–12.3
–15.3
–13.9
140E
140F
200 Vac
200 Vac
15 kW
18 kW
1150
1150
15
18.5
55.6
63.5
6
6
0.084
0.066
3.83
3.33
4.65
4.5
372.1
421.3
0
0
57.5
57.5
190
190
57.5
57.5
2.9
2.9
0.062
0.091
–14.4
–17.9