n
Reinstalling the Terminal Board
1.
Reinstall the removable terminal block on the drive according to
2.
Ensure the terminal block is firmly fastened to the connector.
3.
Put the lower cover and the terminal cover back in place.
4.
After replacing the drive, check the drive unit selection setting in o2-04.
Duty Rating (ND/HD) on page 382
5.
An oPE04 error may occur when replacing the drive or the removable terminal block. If the data saved to the
terminal block is compatible, set A1-03 to 5550 to write the parameter settings stored in the terminal block to the
new drive. Reset the appropriate maintenance monitors using parameters o4-01 to o4-13.
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Figure 7.10 Removable Terminal Board Disconnected from the Drive
Figure 7.11 Terminal Board Reinstallation
Figure 7.12 Terminal Board Reinstalled
for more information.
Figure
7.11.
Place the terminal board below the
guide tracks in the plastic case of the
drive. Then push it gently down and
slide it toward the keypad until the
locking pin clicks into place.
Connector
Refer to Defaults by Drive Model and
7.5 Drive Replacement
301