Q: Driveworksez Parameters; R: Driveworksez Connection Parameters - YASKAWA V1000 Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
o4-12
kWh Monitor Initialization
Number of Run Commands
o4-13
Initialize Selection
<1> Parameter can be changed during run.
<2> Setting range is determined by drive software version.
PRG: 1016 and later: 104 to 810
PRG: 1015 and earlier: 104 to 621
<3> Default setting value is dependent on parameter o1-03, Digital Operator Display Selection.
<4> Parameter setting value is not reset to the default value during drive initialization, A1-03 = 1110, 2220, 3330
<5> Default setting value is dependent on parameter o2-04, Drive Model Selection.
<6> Available in drive software versions PRG: 1011 and later. Parameter o4-03 is set in 10 h units. When o4-03 = 30, the operation time for the
cooling fan will start counting from 300 hours, and monitor U4-03 will display "300 H". Earlier software versions set o4-03 in 1 h units.
<7> Available in drive software versions PRG: 1022 and later.
u

q: DriveWorksEZ Parameters

No.
Name
q1-01 to
DriveWorksEZ
q6-07
Parameters
u

r: DriveWorksEZ Connection Parameters

No.
Name
DriveWorksEZ Connection
r1-01
Parameter 1 (upper)
DriveWorksEZ Connection
r1-02
Parameter 1 (lower)
DriveWorksEZ Connection
r1-03
Parameter 2 (upper)
DriveWorksEZ Connection
r1-04
Parameter 2 (lower)
DriveWorksEZ Connection
r1-05
Parameter 3 (upper)
DriveWorksEZ Connection
r1-06
Parameter 3 (lower)
DriveWorksEZ Connection
r1-07
Parameter 4 (upper)
DriveWorksEZ Connection
r1-08
Parameter 4 (lower)
DriveWorksEZ Connection
r1-09
Parameter 5 (upper)
DriveWorksEZ Connection
r1-10
Parameter 5 (lower)
DriveWorksEZ Connection
r1-11
Parameter 6 (upper)
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
0: U4-10 and U4-11 monitor data are not reset when the drive
is initialized using A1-03.
1: U4-10 and U4-11 monitor data are reset when the drive is
initialized using A1-03. (The value of o4-12 is automatically
returned to 0.)
0: U4-02 monitor data is not reset when the drive is
initialized using A1-03.
1: U4-02 monitor data is reset when the drive is initialized
using A1-03. (The value of o4-13 is automatically returned
to 0.)
Description
Reserved for DriveWorksEZ.
Description
Parameter 1 for connecting DriveWorksEZ (upper).
Parameter 1 for connecting DriveWorksEZ (lower).
Parameter 2 for connecting DriveWorksEZ (upper).
Parameter 1 for connecting DriveWorksEZ (lower).
Parameter 1 for connecting DriveWorksEZ (upper).
Parameter 3 for connecting DriveWorksEZ (lower).
Parameter 4 for connecting DriveWorksEZ (upper).
Parameter 4 for connecting DriveWorksEZ (lower).
Parameter 5 for connecting DriveWorksEZ (upper).
Parameter 5 for connecting DriveWorksEZ (lower).
Parameter 6 for connecting DriveWorksEZ (upper).
B.2 Parameter Table
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0, 1
0
A A A
0, 1
0
A A A
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
-
-
A A Α
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
0 to
0
– A A
FFFFH
Addr.
Pg.
Hex
512
240
528
240
Addr.
Pg.
Hex
-
Addr.
Pg.
Hex
1840
1841
1842
1843
1844
1845
1846
1847
1848
B
1849
184A
369