3.3

Main Circuit Connection Diagram

Refer to diagrams in this section for the Main Circuit wiring connections. Connections may vary based on drive capacity.
The main circuit DC power supply powers the control circuit.
NOTICE: Do not use the negative DC bus terminal "-" as a ground terminal. This terminal is at high voltage DC potential. Improper
wiring connections could result in damage to the drive.
u

Single-Phase 200 V Class Models BA0001 to BA0018

NOTICE: Do not connect T/L3 terminal when using single-phase power supply input. Incorrect wiring may damage the drive.
u
Three-Phase 200 V Class Models 2A0001 to 2A0069
Three-Phase 400 V Class Models 4A0001 to 4A0038
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
DC reactor
(option)
Jumper
+2
+1
R/L1
S/L2
Single-phase
200 Vac
Figure 3.3 Connecting Single-Phase Main Circuit Terminals
DC reactor
(option)
Jumper
+2
R/L1
S/L2
T/L3
Three phase 200 Vac
(400 Vac)
Figure 3.4 Connecting Three-Phase Main Circuit Terminals

3.3 Main Circuit Connection Diagram

Braking Resistor
Unit (option)
B1 B2
Drive
U/T1
V/T2
Motor
W/T3
Braking
Resistor Unit
(option)
+1
B1 B2
Drive
U/T1
V/T2
Motor
W/T3
3