F: Options

F parameters are used to program the drive for PG feedback and to function with option cards.
No.
Name
Operation Selection at PG
F1-02
Open Circuit (PGo)
Operation Selection at
F1-03
Overspeed (oS)
Operation Selection at
F1-04
Deviation
F1-08
Overspeed Detection Level
Overspeed Detection Delay
F1-09
Time
Excessive Speed Deviation
F1-10
Detection Level
Excessive Speed Deviation
F1-11
Detection Delay Time
PG Open-Circuit Detection
F1-14
Time
Communications Error
F6-01
operation Selection
External fault from comm.
F6-02
option selection
External fault from comm.
F6-03
option operation selection
F6-04
Bus Error Detection Time
F6-07
NetRef/ComRef Function
<6>
Selection
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Description
F1: V/f Control with Simple PG Feedback - PG Setup Parameters
Use F1 parameters to set up the drive for V/f Control with Simple PG Feedback.
These parameters are enabled only when H6-01 = 03
Sets stopping method when a PG open circuit fault (PGo)
occurs. Refer to parameter F1-14.
0: Ramp to Stop - Decelerate to stop using the active
deceleration time.
1: Coast to Stop
2: Fast-stop - Decelerate to stop using the deceleration time
in C1-09.
3: Alarm only - Drive continues operation.
Sets the stopping method when an overspeed (oS) fault
occurs. Refer to F1-08 and F1-09.
0: Ramp to stop - Decelerate to stop using the active
deceleration time.
1: Coast to stop
2: Fast-stop - Decelerate to stop using the deceleration time
in C1-09.
3: Alarm Only - Drive continues operation.
Sets the stopping method when a speed deviation (dEv) fault
occurs. Refer to F1-10 and F1-11.
0: Ramp to stop - Decelerate to stop using the active
deceleration time.
1: Coast to stop
2: Fast-stop - Decelerate to stop using the deceleration time
in C1-09.
3: Alarm only - Drive continues operation.
Sets the speed feedback level which has to be exceeded for
the time set in F1-09 before an oS fault will occur.
Set as a percentage of the maximum output frequency
(E1-04).
Sets the time in seconds for which the speed feedback has to
exceed the overspeed detection level F1-08 before an oS
fault will occur.
Sets the allowable deviation between motor speed and
frequency reference before a speed deviation fault (dEv) is
triggered.
Set as a percentage of the maximum output frequency
(E1-04).
Sets the time in seconds for which a deviation between motor
speed and frequency reference has to exceed the speed
deviation detection level F1-10 before a dEv fault will occur.
Sets the time for which no PG pulses must be detected before
a PG Open (PGo) fault is triggered.
F6: Serial Communications Option Card Settings
Use F6 parameters to program the drive for serial communication.
Selects the operation after a communications error occurred.
0: Ramp to stop using current accel/decel time
1: Coast to stop
2: Fast-stop using C1-09
3: Alarm only
Sets when an external fault from a comm option is detected.
0: Always detected
1: Detection during Run only
Selects the operation after an external fault set by a
communications option (EF0).
0: Ramp to stop using current accel/decel time
1: Coast to stop
2: Fast-stop using C1-09
3: Alarm only
Set the delay time for error detection if a bus error occurs. 0.0 to 5.0 2.0 s
0: Multi-step reference disabled (same as F7)
1: Multi-step reference enabled (same as V7)
B.2 Parameter Table
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0 to 3
1
A
0 to 3
1
A
0 to 3
3
A
0 to 120 115% A
0.0 to 2.0
1.0
A
0 to 50
10%
A
0.0 to
0.5 s
A
10.0
0.0 to
2.0 s
A
10.0
0 to 3
1
A A A
0, 1
0
A A A
0 to 3
1
A A A
A A A
0, 1
0
A A A
Addr.
Pg.
Hex
381
173
382
173
383
173
387
173
388
173
389
173
38A
173
38D
174
3A2
174
3A3
174
3A4
174
B
3A5
3A8
174
347