E: Motor Parameters - YASKAWA V1000 Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

B.2 Parameter Table
<3> Range upper limit is dependent on parameters E1-04, Maximum Output Frequency, and d2-01, Frequency Reference Upper Limit.
<4> Default setting is determined by the drive software version.
PRG: 1016 and later: 100.00%
PRG: 1015 and earlier: 0.00 %
u

E: Motor Parameters

No.
Name
E1-01
Input Voltage
<1>
Setting
E1-03
V/f Pattern
<2>
Selection
Maximum Output
E1-04
Frequency
E1-05
Maximum Output
<1>
Voltage
E1-06
Base Frequency
Middle Output
E1-07
Frequency
E1-08
Middle Output
<1>
Frequency Voltage
Minimum Output
E1-09
Frequency
E1-10
Minimum Output
<1>
Frequency Voltage
E1-11
Middle Output
Frequency 2
E1-12
Middle Output
<1>
Frequency Voltage
2
<7>
E1-13
Base Voltage
<1> <9>
342
Description
E1: V/f Pattern Characteristics
Use E1 parameters to set V/f characteristics for the motor.
This parameter must be set to the power supply voltage. It
sets the maximum and base voltage used by preset V/f
patterns (E1-03 = 0 to E) and adjusts levels used by certain
functions.
WARNING! Electrical Shock Hazard. Drive input
voltage (not motor voltage) must be set in E1-01 for the
protective features of the drive to function properly. failure
to do so may result in equipment damage and/or death or
personal injury.
Selects a preset V/f pattern.
0: 50 Hz Constant torque 1
1: 60 Hz Constant torque 2
2: 60 Hz Constant torque 3 (50 Hz base)
3: 72 Hz Constant torque 4 (60 Hz base)
4: 50 Hz Variable torque 1
5: 50 Hz Variable torque 2
6: 60 Hz Variable torque 3
7: 60 Hz Variable torque 4
8: 50 Hz High starting torque 1
9: 50 Hz High starting torque 2
A: 60 Hz High starting torque 3
B: 60 Hz High starting torque 4
C: 90 Hz (60 Hz base)
D: 120 Hz (60 Hz base)
E: 180 Hz (60 Hz base)
F: Custom V/f. E1-04 through E1-13 settings define the
V/f pattern
E1-04 and E1-06 to E1-13 can only be changed when
E1-03 is set to F. To set linear V/f characteristics, set the
same values for E1-07 and E1-09. In this case, the setting
for E1-08 will be disregarded.
When E1-13 = 0.0 V, then the drive uses the value set to
E1-05 to control the voltage level.
Ensure that the five frequencies are set according to these
rules to prevent triggering an oPE10 fault:
E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04
Note: Setting E1-11 to 0 disables both E1-11 and E1-12,
and the above conditions do not apply.
VACrms Out(V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09 E1-07
Frequency (Hz)
Use E2 parameters to set motor-related data.
E1-06 E1-11 E1-04
E2: Motor Parameters
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/f
LV PM
155 to 255
200 V
S
S
0 to F
F
A
A
60 Hz
40.0 to
<4>
400.0
S
S
<3>
<19>
200 V
0.0 to
S
S
<4>
255.0
60 Hz
0.0 to
S
S
<4> <19>
E1-04
3.0 Hz
0.0 to
<3>
A
A
E1-04
<19>
16.0 V
0.0 to
A
A
<5> <6>
255.0
1.5 Hz
0.0 to
<5> <4>
S
S
E1-04
<19>
9.0 V
0.0 to
A
A
<5> <6>
255.0
0.0 to
0.0 Hz
A
A
E1-04
0.0 to
0.0 V
A
A
255.0
0.0 to
0.0 V
A
S
255.0
Addr. Hex Pg.
S
300
162
302
162
S
303
165
S
304
165
S
305
165
-
306
165
-
307
165
S
308
165
-
309
165
-
30A
165
-
30B
165
-
30C
165