Advertisement

5.5 E: Motor Parameters
n
E4-10: Motor 2 Iron Loss
Sets the motor 2 iron loss in watts.
No.
E4-10
n
E4-11: Motor 2 Rated Power
Sets the motor 2 rated power. During Auto-Tuning the value must entered to parameter T1-02. If Auto-Tuning completes
successfully, the entered value will automatically be saved to E4-11.
No.
E4-11
n
E4-12: Motor 2 Iron-Core Saturation Coefficient 3
Sets the motor 2 iron saturation coefficient at 130% of magnetic flux.
No.
E4-12
n
E4-14: Motor 2 Slip Compensation Gain
Instead of C3-01 the value of E4-14 is used as gain for slip compensation when motor 2 is selected.
Compensation Gain on page 146
No.
E4-14
n
E4-15: Motor 2 Torque Compensation Gain
Instead of C4-01 the value of E4-15 is used as gain for torque compensation when motor 2 is selected.
Torque Compensation Gain on page 147
No.
E4-15
u

E5: PM Motor Settings

These parameters set the motor data of a PM motor used in OLV for PM (A1-02 = 5).
When Yaskawa motors are used, entering the motor code written on the motor nameplate will set up the E5-oo parameters.
For all other PM motors, the data must be entered manually.
n
E5-01: PM Motor Code Selection
Set the motor code for the PM motor being used. Depending on the motor code entered, the drive automatically sets several
parameters to appropriate values.
details on the supported motor codes and their parameter settings.
No.
E5-01
Note:
1. This parameter is not reset when the drive is initialized using parameter A1-03.
2. The default setting is for a Yaskawa SMRA Series SPM Motor with a speed rating of 1800 r/min.
3. Changing the motor code setting resets all E5-oo settings to their default values.
4. Set to "FFFF" when using a non-Yaskawa PM motor or one that is not supported by the motor code settings.
Figure 5.44
explains the motor code setting.
170
Parameter Name
Motor 2 Iron Loss
Parameter Name
Motor 2 Rated Power
Parameter Name
Motor 2 Iron-Core Saturation Coefficient 3
for details and setting instructions.
Parameter Name
Motor 2 Slip Compensation Gain
for details and setting instructions.
Parameter Name
Motor 2 Torque Compensation Gain
Refer to Parameters that Change with the Motor Code Selection on page 390
Parameter Name
PM Motor Code Selection
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Setting Range
0 to 65535 W
Setting Range
0.00 to 650.00 kW
Setting Range
1.30 to 5.00
Refer to C3-01: Slip
Setting Range
0.0 to 2.50
Refer to C4-01:
Setting Range
0.0 to 2.50
Setting Range
0000 to FFFF
Default
Depending on
o2-04
Default
Depending on
o2-04
Default
1.30
Default
Depending on
E3-01
Default
1.00
for
Default
Depending on
o2-04