YASKAWA V1000 Technical Manual page 353

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

H2-oo
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
Frequency reference selection Open: External Reference 1 or 2 supplies the frequency reference
9
A
Run command selection
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Not used/Through Mode
10
Minor Fault
11
Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 (N.C.)
18
Torque Detection 2 (N.O.)
19
Torque Detection 2 (N.C.)
1A
Reverse Direction
1B
During Baseblock (N.C.)
1C
Motor 2 Selection
1E
Restart Enabled
1F
Overload Alarm oL1
20
oH Pre alarm
Mechanical Weakening
22
(N.O.)
2F
Maintenance Period
<1>
30
During Torque Limit
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
H2 Multi-Function Digital Output Settings
Closed: A Run command is active or voltage is output.
Closed: Output frequency is 0.
Closed: Output frequency equals the speed reference (plus or minus the hysteresis
set to L4-02).
Closed: Output frequency and speed reference equal the value in L4-01 (plus or minus
the hysteresis of L4-02).
Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis
determined by L4-02.
Closed: Output frequency is greater than or equal to the value in L4-01, with
hysteresis determined by L4-02.
Closed: Drive Ready. The drive is powered up, not in a fault state, and in the Drive
mode.
Closed: DC bus voltage is below the Uv trip level set in L2-05.
Closed: There is no output voltage
Closed: Digital operator supplies the frequency reference.
Open: External Reference 1 or 2 supplies the Run command
Closed: Digital operator supplies the Run command.
Closed: Output current/torque exceeds the torque value set in parameter L6-02 for
longer than the time set in parameter L6-03.
Closed: Loss of the analog frequency reference detected. Enabled when L4-05 = 1. O O O
Closed: Braking resistor or transistor is overheated or faulted out. This selection
requires that braking resistor protection parameter be set for ERF (L8-01 = "1").
Closed: Fault occurred (other than CPF00 and CPF01).
Set this value when the terminal is not used, or when using the terminal in the pass-
through mode.
Closed: An alarm is triggered.
Closed: The drive has received a reset command from the multi-function input
terminals or from serial network, or the digital operator RESET key has been pressed.
Timer output, controlled by b4-01 and b4-02. Used in conjunction with the digital
input (H1-oo = 18 "timer function").
Closed: When drive output frequency equals the frequency reference +/- L4-04.
Closed: When the drive output frequency is equal to the value in L4-03 (plus or minus
L4-04).
Closed: When the drive output frequency is less than or equal to the value in L4-03
with the hysteresis determined by L4-04.
Closed: When the output frequency is greater than or equal to the value in L4-03 with
the hysteresis determined by L4-04.
Open: When the output current/torque exceeds the value set in parameter L6-02 for
more time than is set in parameter L6-03.
Closed: When the output current/torque exceeds the value set in parameter L6-05 for
more time than is set in parameter L6-06.
Open: Output current/torque exceeds the value set in parameter L6-05 for more time
than is set in parameter L6-06.
Closed: Drive is running in the reverse direction.
Open: Drive is in Baseblock condition. Output is disabled.
Closed: Motor 2 is selected by a digital input (H1-oo = 16)
Closed: An automatic restart is performed
Closed: oL1 is at 90% of its trip point or greater.
Closed: Heatsink temperature exceeds the parameter L8-02 value.
Closed: Mechanical Weakening detected.
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay
may require maintenance.
Closed: When the torque limit has been reached.
Description
B.2 Parameter Table
Control
Mode
Pg.
O
V/
P
L
f
M
V
O O O
187
O O O
187
O O O
187
O O O
188
O O O
188
O O O
189
O O O
189
O O O
189
O O O
190
O O O
190
O O O
190
O O O
190
190
O O O
190
O O O
190
O O O
190
O O O
190
O O O
190
O O O
191
O O O
191
O O O
191
O O O
191
O O O
192
O O O
190
O O O
190
O O O
190
O O O
192
O O O
193
O O −
193
O O O
193
O O O
193
O O O
193
O O O
193
O O O
193
− O −
193
353