Table column
Batch runtime
Order category
Order
Master recipe
Formula
RUP (recipe unit
procedure)
RUP runtime
ROP (recipe opera‐
tion)
ROP runtime
Shortcut menu in the control
The commands available in the shortcut menu in the control are described based on examples
in the following table.
The commands are essentially operator commands for active batches, like those listed
previously for the SIMATIC BATCH OS Process Cell control.
Symbol
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
Description
The batch runtime deter‐
mined by the system
Name of the order category
Name of the order.
Name of the master recipe
Name of the used formula
Symbol of the RUP, status
symbol of the RUP, name of
the RUP
The runtime for a recipe unit
procedure (RUP) determined
by the system. If a time-out
occurs, a time symbol is dis‐
played.
Symbol of the ROP, status
symbol of the ROP, name of
the ROP If wait steps occur, a
time symbol is displayed.
Italic font if more than one
ROP is active.
The runtime for a recipe oper‐
ation determined by the sys‐
tem. If a time-out occurs, a
time symbol is displayed.
Shortcut menu
Symbol
command
Unit
Symbol
Subcommand
Meaning
Revoke release
Use this command to revoke the unit
enable for SIMATIC BATCH. This
means that SIMATIC BATCH cannot
occupy this unit.
Register for mainte‐
Use this command to sign on the unit
nance
for maintenance.
BATCH OS controls
11.3 Operations in process mode
Meaning
-