Context help references
14.1 Dialogs
Properties
Name of the object selected in the process cell tree.
Description
Process cell component
grouping
CFC chart
"Open" button
Not possible in the multi‐
project.
Assigned operation type
"Type" button
Control strategies
"Change" button
Batch process cell
Buttons
Compile
This button only exists for
a project and not for a
multiproject.
Log
"Errors" display field
"Warnings" display field
"Display" button
Additional functions
Display of possible additional functions.
922
The description of the equipment operation is displayed in this text box.
You enter description texts in the object properties in SIMATIC Manager.
Runtime name: Corresponds to the WinCC variable name plus the OS
name as prefix.
CFC chart name in which the block is placed.
Click on the "Open" button to open the appropriate CFC chart and select
the block.
Type definition for process cell-neutral recipe creation.
Activating this button takes you to the corresponding operation type. With
the "Back" button of the operation type, you return to beginning selection.
If the assigned operation type was defined as a control strategy type, you
can exclude certain control strategies from the control strategies defined
for the type using the "Change" button. The control strategies excluded in
this manner will no longer be available for this instance in batch control. For
SFC types this is not possible because the control strategies are defined
in the block. If a control strategy is not defined the line will not be displayed.
Use the "Change" button to exclude certain control strategies from all the
control strategies defined on the type
All batch instance blocks of the CFC chart of the selected object are read
in. This also implicitly involves a check for consistency with the batch types
and conformity to ISA-88.
The number of errors for the selected log is displayed.
The number of warnings for the selected log is displayed.
The logging is activated with the "Display" button. The selected log is
generated as an XML file in the specified layout and displayed in In‐
ternet Explorer.
Select "Process cell" and click the "Display" button to show all process
cell errors or warnings. You can also right-click a selected object and
select the "Display log" function to display object-specific errors or
warnings.
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA