This button reads in the process cell topology again and therefore updates the data in this
dialog.
To ensure that all changed data have been correctly taken into consideration for an action
from the SB configuration dialog, "Configure batch process cell', you should execute this
function prior to any such action.
14.1.12.62

"Chart folder" tab

What tasks do you perform in the "Chart folder" tab?
In the "Chart folder" tab, you update, compile and download the charts of your S7 program
and the memory blocks required for AS-based mode to the AS. If you use a multiproject, each
project can contain an AS and therefore a chart folder in which the charts must be compiled
as program and downloaded.
Requirements for AS-based mode
● To be able to use the "AS-based" mode, the memory configuration for code and data must
be specified in MB in the BATCH configuration dialog in the properties of the CPU as well
as the percentage of this memory allocated to the recipe logic.
● For each AS, there must be a CFC chart (@ASB_Mem) in which the memory blocks
(MemIDB64) are placed. Depending on your settings for the memory configuration, the
number of CFC charts and the memory blocks contained in them will be recalculated and
adapted according to a formula by the system. This adaptation may mean regenerating,
adding or deleting CFC charts or memory blocks and is performed automatically by the
system when updating if changes were made in the basic engineering. Remember that the
number of CFC charts is decisive for the memory space on the AS.
● Before these configurations can be undertaken by the system, the SIMATIC BATCH blocks
must be already installed and included in the block folder of the project.
How are the dialog and its tabs displayed?
You open the "Compile/Download" dialog if you have selected the "Stations" folder or the
"SIMATIC station" folder in the BATCH configuration dialog and then click the "Compile /
Download..." button. Then click on the "Chart folder" tab.
Layout of the tab
The meaning of the column headers, the information contained in the table, and the functions
that can be used (buttons and check boxes) are described below.
Name
Name of the CFC chart @ASB_Mem containing the MemIDB64 memory blocks. The CFC
chart originates from the chart folder in the basic engineering.
SIMATIC BATCH V8.2