Properties
Name of the object selected in the process cell tree.
Description
Assigned data type
"Data type" button
Assigned unit of measure Assign the unit of measure to the type parameter. You must declare re‐
"Unit of measure" button
"Archive measured val‐
ue" check box
"Test manufacturing in‐
struction" check box
"Control strategy parame‐
ter" check box
Events log ID:
Parameters
Button
Delete
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
You can display or enter the description of the operation type parameter in
this text box.
Assign the required data type to the type parameter. All standard data types
and user data types are available for selection. You must declare required
user data types under the shared declarations and make them available by
using the "Generate" function in SIMATIC BATCH.
Activating this button takes you to the corresponding data type. With the
"Back" button of the data type, you return to beginning selection.
quired units of measure under "Units of measure" in the shared declarations
and make them available by using the "Generate" function in SIMATIC
BATCH.
Activating this button takes you to the appropriate unit. With the "Back"
button of the unit of measure, you return to this location.
Select this check box if you wish to establish a connection to a WinCC
archive tag for the instance parameters. This selection is required for as‐
signing instance parameters to WinCC archive tags. You then make this
assignment on the instance parameters of the corresponding operation
type.
A type parameter is selected here if it is to be provided in the batch log for
the manual check (manufacturing instruction).
If this check box is selected, you can make the control strategy settings for
this type at the type parameter.
This option is only available after at least one control strategy type has been
configured under data types.
Here, you can specify a value from 0 to 65535 that can be evaluated later
in a user batch report to allow filtering. Different values are permitted for
setpoint and process value. This means, for example, that you could filter
according to setpoints with setpoint ID < 1000 AND setpoint ID ≥ 500 and
according to process values with process value ID ≤ 2000. The user can
specify how convenient such a query is in his log software.
Click "Delete" to delete the selected operation type parameter.