Import - Assign Parameters - Siemens SIMATIC BATCH Operating Manual

Process control system pcs 7
Table of Contents

Advertisement

Context help references
14.2 BCC menu commands
Comparison if there are differences between source and target process cell
Because objects are not imported in the batch process cell, but rather replaced, direct
activation of a check box by clicking in the left column is not possible here. The check box is
selected automatically if an object from the right column is selected for replacement.
Replace with
The "Available elements" window shows the unassigned elements of the open process cell
matching the element selected in the left window. By double-clicking an element in this list,
you assign the element to element selected in the tree. All underlying elements are also
assigned. Any existing assignment is automatically deleted by this action.
Deleting assignments
If you click the check box in the tree, the assignment is removed.
Back
Goes to the previous page. The previously configured data (allocations) remain intact.
Next
Goes to the next page. If the data on the current page are incomplete, a warning appears and
the element creating the problem is marked on the left.
14.2.7.4

Import - Assign Parameters

Introduction
Additional assignments must be made for formula categories and libraries. When a formula
category is replaced, for example, information must be provided as to how the interconnected
parameters must be replaced.
The library or formula category assignments are listed in the drop-down list of "affected
assignments". You need to define how the corresponding parameters are to be interconnected
for each of these assignments. The Import Assistant makes the assignments as much as
possible by comparing names.
Check and correct these as necessary. If you cannot make an assignment, remove the check
mark in the check box of the respective row. If you exclude one or more elements, the imported
recipe/library/formula category is not valid.
● The parameters of the elements from the import file are listed on the left.
● On the right are the parameters that can be entered in the currently selected line in the left
list.
1086
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA

Hide quick links:

Advertisement

Table of Contents
loading