6-8
Integration Volume
Each Octel 200/300 port extension must have the following capabilities. For some SL-1 installations,
these capabilities must be specifically configured for each Octel 200/300 port extension by COS (Class of
Service).
Ability to send DTMF tones (DTN)
-
Ability to follow the hunting sequence on busy (HTA)
-
Ability to perform a hookswitch transfer (XFA)
-
Ability to forward calls on a no-answer condition (FNA)
-
Ability to forward all calls through a command sequence from the phone. Also, the ability to cancel
-
the forwarding (CFW)
High Priority Allowed (HPR)
-

SLIC Link Digit Display Telephone Extensions

The SLIC board has four digit display extensions:
Integration Unit 1, Link 1
-
Integration Unit 2, Link 1
-
Each Integration Unit is responsible for up to 16 ports of integrated call processing.
.
If the system has more than 16 ports, a second SLIC board is required to support message waiting
commands.
The configuration steps that follow pertain to a single Integration Unit within a card. Repeat these steps
to configure both Integration Units.
.
The overflow extension must not be configured as an appearance on the digit display set. The
primary directory number assigned for each link must be a unique extension.
The SL-1 digit display set must be configured to have two extra rows of buttons (the 20 key add on
module) for Octel 200/300 port appearances.
Each SL-1 digit display set link into the Octel 200/300 SLIC must be specifically configured for its Octel
200/300 SLIC link extension and must have the following capabilities.
Digit display on the SL-1 digit display set (ADD — allow digit display)
-
Message waiting capability (MWC — allow message waiting)
-
High priority allowed (HPR)
-
SL-1 Digit Display Set Keyboard Layout
The following are the key configurations for the SL-1 digit display set. The keys must be configured into
the same locations for
Figure 6-1 shows the required key layout for testing for up to 16 ports followed by the SL-1 configuration
commands required to create this layout.
In systems with more than 16 ports, the ports are divided between the integration units in an alternating
fashion. See Figure 6-1 and Table 6-1 for key layout for testing. Integration Unit 1 is programmed with
all odd numbered ports and Integration Unit 2 with all even ports.
Octel 200/300
S.4.1
Integration Unit 1, Link 2
-
Integration Unit 2, Link 2
-
PB60019-01