7.1-8
Integration Volume
7.1.3 DEFINITY G3 CONFIGURATION
Several changes must be made to the DEFINITY G3i configuration to use Adaptive Integration features.
The DEFINITY G3i configuration used for the Octel 200/300 with Adaptive Integration is substantially
different from the configuration used for a non-integrated Octel 200/300.
The changes to the configuration of the DEFINITY G3i are divided into seven sections.
COR (Class of Restriction)
-
ATTIC Link Digital Telephone Extensions
-
ATTIC Link Hunt Group
-
Octel 200/300 Port Extensions
-
Coverage Paths
-
Trunk Groups
-
Station Extensions
-
.
In this chapter, the two ATTIC links are referred to as Link 1 and Link 2.
Naming Conventions
The DEFINITY G3i allows each extension, pilot number or trunk group to have an alphanumeric name.
This name may be up to 15 characters long. If an extension is given a name, Adaptive Integration
requires that it meet certain restrictions. The port extensions and the link extensions must be given
names.
Telephone Extensions
Trunk Groups
Octel 200/300 Port
Extensions
Link Extensions
Octel 200/300
S.4.1
The name must contain the string XXXX
where XXXX is the extension number.
The number must not be preceded with T-, A-, or D-.
The name must contain the string T-XXXX
where XXXX is the trunk group number assigned in the Octel 200/300
TRUNK GROUP Table.
It is recommended that the T be in upper case.
The name must contain the string D-XXXX
where XXXX is the extension number of the Octel 200/300 port.
It is recommended that the D be in upper case.
The name must contain the string A-XXXX
where XXXX is the extension number of the Octel 200/300 digital link
port, or pilot number.
It is recommended that the A be in upper case.
PB60019-01