8.2-30 Integration Volume

8.2.7 ROLM ADAPTIVE INTEGRATION MAINTENANCE

The following are the maintenance commands for the ROLM integration. All commands refer to a slot
number and integration unit number.
Test Integration
TE INT x y
List Integration
L INT
x y
Clear Integration
C INT
x y
Octel 200/300
S.4.1
This command tells the RIC to run its link selftest. The command is
TE INT x y
where x is the slot number.
where y is the integration unit number (1 or 2).
Any hardware errors found are logged in the Hardware Error Table.
Refer to the Installation and Maintenance volume, System Errors and
Traffic Pegs chapter, for more information.
The following command to reset the RIC board is used when changes
necessitate restarting the integration.
TE INT x yx y4 2
where x is the slot number.
where y is the integration unit number (1 or 2).
where 2 is the reset command flag.
This takes approximately 30 seconds.
This command lists the current state of the RIC board, the diagnostic
status, the status of the links, and the pegs. The command is
L INT
x y
where x is the slot number.
where y is the integration unit number (1 or 2).
This command clears the RIC board pegs. The command is
C INT x y
where x is the slot number.
where y is the integration unit number (1 or 2).
PB60019-01