Testing Procedure - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

7.2-32
Integration Volume

Testing Procedure

After the test extensions are configured and the AT&T System 75 is prepared for testing, begin the testing
procedures.
1. PRELIMINARY ANALOG EXTENSION TEST (New installations only)
This test verifies that dial tone is present on each of the single line analog extensions used for
the Octel 200/300 ports.
a.
b. Connect the modular adapter to the 25-pair cable associated with slot 1.
c.
d. Go off-hook. Is dial tone present?
2. PRELIMINARY DIGITAL EXTENSION TEST
This test verifies that dial tone is present on the digital extensions used for the ATTIC links.
.
a.
b. Connect the phone to the jack position of the adapter that corresponds to Integration Unit 1,
c.
d. Press the first line appearance button and verify that the red and green lamp next to the
e.
f.
g. Repeat steps a. through f. to test all other configured slots and links.
Octel 200/300
S.4.1
Disconnect the 25-pair cables from the back of Octel 200/300.
Connect a 2500-type single line telephone to the first jack position of the adapter.
.
Only the first four jack positions of the modular adapter are used per cable.
YES
Repeat B, C and D for all extensions and cables for each slot configured with
'
line cards.
NO
Determine the cause and correct the problem before continuing.
'
If your test set requires an external power source, you will also need the 400B2 external
power adapter.
Connect the 356A modular adapter to the 25-pair cable associated with the configured slot.
Link 1 of the ATTIC.
Press the NORMAL button on the 7407D display phone; verify that the green lamp next to the
NORMAL button is ON.
appearance is ON steady.
NO
Determine the cause and correct the problem before continuing. Check the line
'
appearances in the PBX configuration. Refer to Figure 7.2-4.
Repeat step d. for each of the line appearances that are configured.
Connect the digital phone to the jack position of the modular adapter associated with the next
link.
PB60019-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents