Mci Call Records - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

5.6

MCI CALL RECORDS

The call record the Octel 200/300 receives from the NEAX-2400 contains a combination of ASCII
characters. The first few characters indicate whether the call record is for a direct or forwarded call.
Standard MCI call records can support six digits in d, x, and z fields, and have the following format:
<STX>0!J001dddddd __cc001xxxxxx001zzzzzz<ETX>
or
<STX>0!J001dddddd__cc201yyyttt001zzzzzz<ETX>
.
If the extension is less than six digits long, the field is filled with trailing spaces.
The Octel 200/300 supports the expanded MCI call records format. This format allows eight digits to
identify the port extension and for calling and called party information. The expanded MCI format
introduces a new field currently referred to as "spare." Spare is eight spaces between the calling party
field and the called party field. System Parameter 224 — PBX USES NEC LONG EXTENSION
FORMAT, must be modified to accept records using the long extension format if they are sent from the
switch.
The format is as follows:
<STX>0!J001dddddddd _ _cc001xxxxxxxx ********001zzzzzzzz <ETX>
Where the information is represented by the following abbreviations:
<STX>
<ETX>
0!J
001dddddd
cc
001xxxxxx
201yyyttt
001zzzzzz
_
*
PB60019-01
special control character indicating start of record
special control character indicating end of record
message desk (incoming call record)
destination party, where dddddd is the corresponding Octel 200/300 port extension
number the call came in on
is one of the following:
40
=
forwarded on Ring No Answer ("doesn't answer")
41
=
forwarded on a Busy call ("is busy")
42
=
forwarded All Calls ("is unavailable")
43
=
direct call to the Octel 200/300 station ("to enter
your mailbox...") or trunk (plays company greeting)
44
=
trunk call extended to the Octel 200/300 by the attendant
45
=
trunk call extended to the Octel 200/300 from a station
calling party whose extension is xxxxxx
calling party is trunk, yyy is the Trunk Group number (NEC documentation refers to
this as the Route Number) and ttt is trunk number
called party whose extension number is zzzzzz
indicates a space separating information
indicates the "spare" field for the expanded MCI call records format. It is eight spaces.
NEAX-2400 Adaptive Integration
Octel 200/300
5-11
S.4.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents