6-32
Integration Volume
6.7

SL-1 ADAPTIVE INTEGRATION MAINTENANCE

The following are the maintenance commands for the SL-1 integration. All commands refer to a slot
number and integration unit number.
TEST INTEGRATION
TE INT x
LIST INTEGRATION
L INT x y
CLEAR INTEGRATION
(C INT x y)
Octel 200/300
S.4.1
This command tells the SLIC to run its link selftest. The form of the
y
command is
TE INT x y
where x is the slot number
where y is the integration unit number (1 or 2)
Any hardware errors found are logged in the Hardware Error Table.
Refer to the Installation and Maintenance volume, System Errors and
Traffic Pegs chapter, for more information.
The command to reset the SLIC board is
TE INT
where is the slot number
where 2 is the reset command flag
This command lists the current state of the SLIC
board, the diagnostic status, the status of the links, and
the pegs. The form of the command is
L INT
where x is the slot number
This command clears the SLIC board pegs. The form of the command is
C INT x y
where x is the slot number
PB60019-01