7.2-54
Integration Volume
Item
Description
1.
List the current System 75 stations.
2.
Change the stations name field to fit this format: First XXX Last.
3.
Assign a coverage path to the station using the Coverage Path entry.
4.
MWI only. If the station has a message waiting indicator, be sure to
enable Leave Word Calling by entering Y in LWC reception.
5.
Repeat steps 2 through 4 for each station to be integrated.
Actual Installation
Item
Description
1.
Assign a COS with Attribute 9 to those mailboxes of
extension that should have message waiting indication
(MWI).
2.
Modify System Parameter 3 to be the model number of
your PBX.
3.
Modify System Parameter 116 to be YES.
4.
Mailbox and extension numbers should match.
5.
Modify System Parameter 170 to be YES.
Item
Description
1.
Forward the Octel 200/300 ports.
2.
Plug the ATTIC board(s) into the configured slot(s).
3.
Refer to the power-on routine and monitor the LEDs.
4.
Plug the 25-pair cable into the ATTIC slot.
Octel 200/300
S.4.1
Table 7.2-8 Station Configuration Checklist
Table 7.2-9 Configuration for MWI
Table 7.2-10 Installing the ATTIC Board
Complete
Complete
Command
.A COS
.M SYS 3
.M SYS 116
.M SYS 170
Command Complete
CD x y z
PB60019-01