10.1.2 Mitel Sx-200 Digital Requirements - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

10.1.2 MITEL SX-200 DIGITAL REQUIREMENTS

The Mitel SX-200 Digital installation requirements are divided into three categories: Hardware,
Software, and Configuration.
Hardware Requirements
The Mitel SX-200 Digital hardware interface for the Octel 200/300 with Adaptive Integration requires
Superset 4 telephone lines to interface to the MIC ports.
MIC Port Extensions. The Mitel SX-200 Digital must provide a Superset 4 line for each MIC port in
the Octel 200/300.
.
In the Mitel SX-200 Digital, both analog Superset line cards, part number 9110-410-000, and
digital COV line cards, part number 9109-020-000, may be available. If so, Superset lines from the
analog line cards are recommended since they send display information more quickly than the
digital COV line cards.
Part number 9109-012-XXX, which supports various peripheral devices, including the Superset 4
DN, does not work with Adaptive Integration.
Cables. One 25-pair cable per slot.
Software Requirements
The following software is required for the Mitel SX-200 Digital:
Release:
-
Options Required In Package: None
-
Configuration Requirements
The Mitel SX-200 Digital configuration must have two unassigned COS available for use with Adaptive
Integration, one for MWI and one for CPI.
PB60019-01
Generic 1000 or later
Mitel SX-200 Digital Adaptive Integration
Octel 200/300
10.1-5
S.4.1

Advertisement