Strapping Diagram For Rs-232C Idea Ii Pba - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

9-6
Integration Volume
Port 1
Port 2
Port 3
Port 4
Only one data port is to be strapped for voice mail data port.
-
Arrows point to new strapping positions. Dotted lines
-
indicate original strapping positions.
Ignore flywire connections with respect to this diagram.
-
Extension Requirements
Extensions must be in a class of service that allows access to voice mail. They should also be allowed the
various levels of forwarding available on the Millennium. Refer to the Octel 200/300 Configuration for
Millennium Integration, COS attributes for Integrated Mailboxes section in this chapter for the class of
service attributes required.
Software Requirements
The voice mail feature of the Millennium requires Generic 6.1 version BAD4 or Generic 6.2, version
AAD4.
.
The necessary data boards and data cables are available from the PBX manufacturer as a Voice
Mail/ACD/Data Applications kit (VMAD), part number 188930-101.
The kit includes the data register board, an IDEA II (RS-422) board, an IDEA II (RS-232C) board,
and an assortment of data cables.
Octel 200/300
S.4.1
Port 1
DSR
Port 2
DSR
Port 3
DSR
Port 4
Original
DSR
Jumper
Positions
Figure 9-2 Strapping Diagram for RS-232C IDEA II PBA