7.2.6 AT&T SYSTEM 75 MAINTENANCE
The following are the maintenance commands for the System 75 integration.
TEST INTEGRATION
TE INT x y
TE INT x y
LIST INTEGRATION
L INT x y
CLEAR INTEGRATION
C INT x y
The following are definitions of the fields displayed when listing the state of the ATTIC board.
Card ID
PB60019-01
AT&T System 75/Definity G1 Adaptive Integration
This command tells the ATTIC to run its link selftest. The form of the
command is
TE INT x y
where x is the slot number
where y is the integration unit number (1 or 2).
Any hardware errors found are logged in the Hardware Error Table.
Refer to Installation and Maintenance, System Errors and Traffic Pegs
chapter, for more information.
This command resets the ATTIC board and takes approximately 30
seconds. The form of the command is
TE INT x y 2x y 2
where x is the slot number
where y is the integration unit number (1 or 2)
where 2 is the reset flag
This command lists the current state of the ATTIC board, the diagnostic
status, the status of the links, and the pegs. The form of the command is
L INT
where x is the slot number
where y is the integration unit number (1 or 2).
This command clears the ATTIC board pegs. The form of the command is
C INT x y
where x is the slot number
where y is the integration unit number (1 or 2).
The CARD ID states the type of equipped integration card. The Octel
200/300 reads this register and reports that this is an ATTIC integration
card.
7.2-47
Octel 200/300
S.4.1