7.1.7 INSTALLATION CHECKLIST

This section offers a checklist of issues relating to the Octel 200/300 and to the DEFINITY G3i. The list
is presented in the order in which the installation process should be followed. For details regarding any
topic, refer to the sections of this chapter pertaining to the issue.

Pre-Installation

Item
Description
1.
DEFINITY G3i must provide analog telephone ports (2500 type) from its
analog line circuit cards to each of the ports in the Octel 200/300 cabinet.
2.
DEFINITY G3i must provide a digital port for each of the ATTIC links.
3.
25-pair cable per slot (male to female).
4.
PBX must be DEFINITY G3i or G3r.
Item
Description
1.
List the database. Highlight areas where changes are
required.
2.
Make note of the following definitions for ports:
Number of ports
-
Port extension number
-
Integrated (Y/N)
-
3.
If different company greetings will be used, enter the
Access Code for each route into the TRUNK GROUP
Table. Obtain Access Code numbers from AT&T vendor.
4.
Set the number of ring cycles before forwarding for all
mailboxes that are forwarded to the Octel 200/300to be one
less than the number of ring cycles in the DEFINITY G3i.
5.
Configure a slot in the SLOTS Table for every integration
card installed.
PB60019-01
Table 7.1-2 DEFINITY G3i Software and Hardware Checklist