Test The Platform And Ground Controls; Test Auxiliary Power Operation - Genie Z-45/22 Service Manual

Boom lift
Hide thumbs Also See for Z-45/22:
Table of Contents

Advertisement

Service Manual - Second Edition
800-610-4101
ActionRental.com
A-9
Check the Tire Pressure
This procedure does not need to
be performed on machines
equipped with the foam-filled tire
option.
An over-inflated tire can explode
and may cause death or serious
injury.
To safeguard maximum stability, achieve optimum
machine handling and minimize tire wear, it is
essential to maintain proper pressure in all air-
filled tires.
1 Check each tire with an air pressure gauge and
add air as needed.
Tire Specifications
Industrial tire
100 psi / 6.89 bar
Rough terrain tire
40 psi / 2.76 bar
A-10
Test the Platform and
Ground Controls
Testing machine functions and the Emergency
Stop buttons for malfunctions is essential for safe
machine operation. An unsafe working condition
exists if any function fails to operate properly or
either Emergency Stop button fails to stop all the
machine functions and shut off the engine. Each
function should activate, operate smoothly and be
free of hesitation, jerking and unusual noise.
1 Start the engine from the ground controls, and
then operate each machine function through a
full cycle.
Result: All machine functions should activate
and operate smoothly.
Part No. 32960
2WD Models
4WD Models
9-14.5LT
14-17.5NHS
14-17.5NHS
28 psi / 1.93 bar
Section 4 - Scheduled Maintenance Procedures
2 Push in the Emergency Stop button to the off
position.
Result: No function should operate, the engine
should stop.
3 Start the engine from the platform controls, and
then operate each machine function through a
full cycle.
Result: All machine functions should activate
and operate smoothly.
4 Push in the Emergency Stop button to the off
position.
Result: No function should operate, the engine
should stop.
A-11

Test Auxiliary Power Operation

Detection of auxiliary power system malfunctions
is essential for safe machine operation. An unsafe
working condition exists if the auxiliary powered
functions do not operate in the event of a main
power loss. Auxiliary power is designed for short
term emergency use only, and excessive use will
result in battery drain and pump damage.
1 Turn the key switch to ground control and pull
out the ground control Emergency Stop button
to the on position.
Genie Z-45/22
TABLE A PROCEDURES
Diesel models: All functions
should stop immediately. The
engine will shut off after 2 or 3
seconds.
As a safety feature, selecting and
operating the ground controls can
override the platform controls,
including the Emergency Stop
button.
Oscillating axle equipped
machines only: From the stowed
position, auxiliary power can not
raise the boom above the drive
limit switch. Auxiliary power can
raise the boom if it is already
raised above the drive limit switch.
4 - 5