Section 4 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-8
Test the Auxiliary Power
Operation
Genie specifications require that
this procedure be performed daily.
Detection of auxiliary power system malfunctions is
essential for safe machine operation. An unsafe
working condition exists if the auxiliary powered
functions do not operate in the event of a main
power loss. When operating the machine on engine
power, selecting auxiliary power will stop the engine
immediately. Auxiliary power is designed for short
term use only and excessive use will result in
battery drain and component damage.
Perform this procedure with the
axles extended and the engine off.
1 Turn the key switch to ground control and pull
out the Emergency Stop button to the
position at both the ground and platform
controls.
2 Simultaneously push and hold the auxiliary
power button and push each boom function
button.
To conserve battery power, test
each function through a partial
cycle.
Result: All boom functions should operate.
3 Turn the key switch to platform controls.
4 Press down the foot switch.
5 Simultaneously press and hold the auxiliary
power button and activate each function control
handle, toggle switch or button.
To conserve battery power, test
each function through a partial
cycle.
Result: All boom functions should operate.
4 - 12
A-9

Test the Tilt Sensor and Alarm

The tilt sensor sounds an alarm located in the
platform when the incline of the turntable exceeds
the rating on the serial plate.
1 Turn the key switch to ground controls and pull
out the Emergency Stop buttons out to the
position at both the
ground and platform
controls.
ON
2 Push one of the LCD screen buttons shown until
TURNTABLE LEVEL X AXIS appears.
Result: The LCD screen should display the
angle in degrees.
3 Push one of the LCD
screen buttons shown
until TURNTABLE LEVEL Y AXIS appears.
Result: The LCD screen should display the
angle in degrees.
S-100 & S-105 & S-120 & S-125
January 2010
Genie requires that this procedure
be performed daily.
Select a level test area. The tilt
alarm should not be sounding prior
to the test.
Be sure the engine is off.
Part No. 62401
REV A
ON