[Sense[1]]:Correction:gain2:State <Boolean; Sense[1]]:Correction:gain2'Tate <Boolean - Agilent Technologies U2000 Series Manual

Usb power sensors
Hide thumbs Also See for U2000 Series:
Table of Contents

Advertisement

7
SENSe Subsystem
[SENSe[1]]:CORRection:GAIN2:STATe <boolean>
This command is used to enable/disable a channel offset for the power sensor
setup. The [SENSe[1]]:CORRection:GAIN2[:INPut]
[:MAGNitude] command is used to enter the loss/gain value.
Syntax
SENS
Example
CORR:GAIN2:STAT ON
Reset Condition
On reset, channel offsets are disabled.
Query
[SENSe[1]]|SENSe2:CORRection:GAIN2:STATe?
The query enters 1 or 0 into the output buffer indicating the status of the
channel offsets.
• 1 is returned if a channel offset is enabled
• 0 is returned if a channel offset is disabled
185
:
1
CORR
:GAIN2
:STAT
This command enables a channel offset.
U2000 Series Programming Guide
Space
0|OFF
1|ON
?

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents