Diagnostic Error Messages - HP StorageWorks 8B - FC Entry Switch Reference Manual

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

Diagnostic Error Messages

This section provides information on the probable cause of a diagnostic error and what actions to
take.
Table 2-4
Message
DIAG-BADINT
Err#1030, 2030
[centralMemoryTest, cmiTest]
DIAG-BUS_TIMEOUT
Err#0BoF, 4040F
[portRegTest,
sramRetentionTest]
DIAG-CAMINIT
Err#223B
[camTest]
DIAG-CAMSID
Err#223C
[camTest]
DIAG-CLEAR_ERR
Err#0001
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
Fabric OS Reference
Diagnostic Error Messages
Description
Port received an unexpected interrupt
ASIC register or ASIC SRAM did not
respond to an ASIC data access
Port failed to initialize due to one of the
following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback mode
Port is not active
ASIC failed SID NO translation test
Port's diag error flag (OK or BAD) is
cleared
ASIC's Central Memory SRAMs did not
complete the BISR within the timeout
period
ASIC's Central Memory SRAMs did not
complete the BISR within the timeout
period
Error detected at the wrong port
Error Messages
Probable Cause
Action
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
Software operational
Retry, reboot or
setup error or main
replace mainboard
board failure
assembly
ASIC failure
Replace mainboard
assembly
Informational Only
None required
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
2
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric osStorageworks fc entry switch 8b

Table of Contents