Table 1-13 portLogShow Command Field Descriptions (Continued)
Field
Possible Values
event
Possible events are:
start
disable
enable
ioctl
Tx
Rx
scn
pstate
rejec
busy
ctin
ctout
errlog
loopscn
create
port
Port number of the affected port.
cmd
Command value description depends on event type:
ioctl
Tx & Rx
scn
pstate
ctin
ctout
errlog
loopscn
Fabric OS Reference
switch start or re-start event
port is disabled
port is enabled
port I/O control is executed
frame is transmitted (class is indicated)
frame is received (class is indicated)
state change notification is posted
port changes physical state
received frame is rejected
received frame is busied
CT based request is received
CT based response is transmitted
message is added to the error log
loop state change notification is posted
task is created
I/O control command code
frame payload size
new state.
new physical state. Refer to Table 1-14 for a list of pstate code values.
CT-subtype: fc = Simple Name Server, f8 = Alias Server.
same as ctin above.
error level (see errShow)
Current loop state during loop initialization. Possible values are:
OLP - offline (disconnected or nonparticipating)
LIP - FL_Port entered INITIALIZING or OPEN_INIT state
LIM - LISM completed, FL_Port became the loop master
BMP - loop initialization completed, FL_Port in MONITORING state
OLD - port transited to the OLD_PORT state
TMO - loop initialization times out