HP StorageWorks 8B - FC Entry Switch Reference Manual page 313

Fabric os reference manual (version 3.0)
Hide thumbs Also See for StorageWorks 8B - FC Entry Switch:
Table of Contents

Advertisement

Table 2-4
Message
DIAG-ERRSTAT
Err#2640-2647, 3040-3047,
3840-3847
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-INIT
Err#264F, 304F, 384F
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-INTNIL
Err#2031
[cmiTest]
DIAG-INTNOTCLR
Err#102C
[centralMemoryTest]
DIAG-LCMEM
Err#1027
[centralMemoryTest,
cmemRetentionTest]
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
Fabric OS Reference
Diagnostic Error Messages (Continued)
Description
Port Error Statistics counter is non-zero,
meaning an error was detected when
receiving frames.
One of the following status errors
occurred.
Enc_in – Encoding error, inside
frame
CRC_err – Cyclic redundancy
check on frame failed
TruncFrm – Truncated frame
FrmTooLong – Frame too long
BadEOF – Bad end of file
Enc_out – Encoding error, outside
frame
BadOrdSet – Bad symbol on
fiber-optic cable
DiscC3 – Discarded Class 3 frames
Port failed to go active in the loopback
mode requested
ASIC failed to get a CMI error
(interrupt)
The interrupt bit could not be cleared
Data read from the Central Memory
location did not match data previously
written into the same location
Central Memory transmit path failure:
ASIC 1 failed to read ASIC 2 using the
transmit path
Error Messages
Probable Cause
Action
ASIC, mainboard,
Replace mainboard
SFP module or fiber
assembly, SFP
cable failure
module or fiber
cable
ASIC, main board,
Replace mainboard
SFP module or fiber
assembly, SFP
cable failure
module or fiber
cable
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
ASIC failure
Replace mainboard
assembly
mainboard failure
Replace mainboard
assembly
2
2-11