switchStatusPolicyShow
Displays the policy parameters that determine the overall switch status.
Synopsis
switchStatusPolicyShow
Availability
all users
Description
Use this command to view the current policy parameters set for the switch. These policy parameters
determine the number of failed or non-operational units allowed for each contributor before
triggering a status change in the switch.
The command will print the current parameters in a three column table format. The first column
specifies the contributor; the second column specifies the minimum number that contributes to the
DOWN/FAILED status; the third column specifies the minimum number that contributes to the
MARGINAL/WARNING status. The default values for the policy parameters are as follows:
Table 1-20 Contributor Value and Status
Contributor
FaultyPorts
MissingGBICs
PowerSupplies
Temperatures
Fans
PortStatus
sgroup ISLStatus
The policy parameters determine the number of failed or non-operational units for each contributor
that trigger a status change in the switch. For example, if the FaultyPorts DOWN parameter is set to
3, and 3 ports fail in the switch, then the status of the switch changes to DOWN.
Operands
None.
Fabric OS Reference
Default Value for
DOWN
2
0
2
2
2
0
2
1
Telnet Commands
Default Value for
MARGINAL
1
0
1
1
1
0
1
1-259